重要文件

M-108

Supelco

MTBSTFA

with 1% t-BDMCS, ampule of 5 × 1 mL, analytical standard, Cerilliant®

同義詞:

N-叔丁基二甲基甲硅烷基-N-甲基三氟乙酰胺,含 1% 叔丁基二甲基氯硅烷, N-甲基-N-叔丁基二甲基甲硅烷基三氟乙酰胺, MTBSTFA + 1% TBDMSCl, 甲硅烷基化混合物VI

登入查看組織和合約定價


About This Item

經驗公式(希爾表示法):
C9H18F3NOSi
CAS號碼:
分子量::
241.33
Beilstein:
3606546
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:

產品名稱

MTBSTFA(含 1%t-BDMCS), ampule of 5 × 1 mL, (with 1% t-BDMCS), analytical standard, Cerilliant®

等級

analytical standard

品質等級

反應適用性

reagent type: derivatization reagent
reaction type: Acylations

包裝

ampule of 5 × 1 mL

製造商/商標名

Cerilliant®

技術

gas chromatography (GC): suitable

應用

forensics and toxicology

形式

neat

儲存溫度

−20°C

SMILES 字串

CN(C(=O)C(F)(F)F)[Si](C)(C)C(C)(C)C

InChI

1S/C9H18F3NOSi/c1-8(2,3)15(5,6)13(4)7(14)9(10,11)12/h1-6H3

InChI 密鑰

QRKUHYFDBWGLHJ-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

應用


  • 环境颗粒物中的药物:一项初步评估。: 本研究探讨了环境颗粒物中存在的药物化合物,使用的分析方法可能涉及MTBSTFA等衍生化试剂。在空气样品中检测到的这些物质表明了其潜在健康影响和环境持久性 (Cecinato et al., 2017)(Cecinato et al., 2017)。


法律資訊

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany

象形圖

FlameExclamation mark

訊號詞

Warning

危險聲明

危險分類

Eye Irrit. 2 - Flam. Liq. 3 - Skin Irrit. 2

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 3

閃點(°F)

113.0 °F - closed cup

閃點(°C)

45 °C - closed cup


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如果您需要協助,請聯絡 客戶支援

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Xiaodong Huang et al.
Analytical chemistry, 80(1), 107-114 (2007-12-07)
This work describes an approach to differential metabolomics that involves stable isotope labeling for relative quantification as part of sample analysis by two-dimensional gas chromatography/mass spectrometry (GCxGC/MS). The polar metabolome in control and experimental samples was extracted and differentially derivatized
Claude Schummer et al.
Talanta, 77(4), 1473-1482 (2008-12-17)
In this study, MTBSTFA and BSTFA, which are among the preferred derivatization reagents for silylation were both tested on derivatization of six different groups of polar chemicals to get information about usefulness in terms of sensitivity and specificity of both
A Royer et al.
Journal of chromatography. A, 1108(1), 129-135 (2006-01-31)
An analytical method has been developed for the determination of residues of ethephon (2-chloroethyl phosphonic acid) in drinking and surface water. The procedure is based on de-ionisation with an anion/cation-exchange resin, solid phase extraction by means of anion-exchange polystyrene-divinylbenzene extraction
Xiaowei Wang et al.
Analytica chimica acta, 753, 57-63 (2012-10-31)
A sample preparation method for the determination of hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) in sediment samples was developed using gas chromatography-mass spectrometry (GC-MS). Dispersive liquid-liquid microextraction (DLLME) with derivatization was performed following the subcritical water extraction (SWE) that provided which
Man-Jeong Paik et al.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 821(1), 94-104 (2005-05-17)
Simultaneous profiling analysis of urinary amino acids (AAs) and carboxylic acids (CAs) was combined with retention index (I) analysis for graphic recognition of abnormal metabolic state. The temperature-programmed I values of the AA and CA standards measured as ethoxycarbonyl (EOC)/methoxime

Global Trade Item Number

庫存單位GTIN
M-108-5X1ML4061833976777

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務