跳轉至內容
Merck
全部照片(1)

重要文件

H-017

Supelco

m-Hydroxybenzoylecgonine solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

登入查看組織和合約定價


About This Item

經驗公式(希爾表示法):
C16H19NO5
CAS號碼:
分子量::
305.33
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:
NACRES:
NA.24

等級

certified reference material

品質等級

形狀

liquid

特點

Snap-N-Spike®/Snap-N-Shoot®

包裝

ampule of 1 mL

製造商/商標名

Cerilliant®

drug control

Narcotic Licence Schedule A (Switzerland)

濃度

1.0 mg/mL in methanol

技術

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

應用

forensics and toxicology

形式

single component solution

儲存溫度

−20°C

SMILES 字串

CN1[C@H]2CC[C@@H]1[C@H]([C@H](C2)OC(=O)c3cccc(O)c3)C(O)=O

InChI

1S/C16H19NO5/c1-17-10-5-6-12(17)14(15(19)20)13(8-10)22-16(21)9-3-2-4-11(18)7-9/h2-4,7,10,12-14,18H,5-6,8H2,1H3,(H,19,20)/t10-,12+,13-,14+/m0/s1

InChI 密鑰

XCJJCRPRQYXLRE-AHLTXXRQSA-N

一般說明

m-Hydroxybenzoylecgonine is a urinary metabolite of cocaine and a biomarker for determination of cocaine use. This Certified Spiking Solution® is applicable to use in urine drug testing, clinical toxicology, or forensic analysis by LC-MS/MS or GC/MS.

法律資訊

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
CERTIFIED SPIKING SOLUTION is a registered trademark of Cerilliant Corporation
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

相關產品

產品號碼
描述
訂價

訊號詞

Danger

危險分類

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

標靶器官

Eyes

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 1

閃點(°F)

49.5 °F - closed cup

閃點(°C)

9.7 °C - closed cup


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如果您需要協助,請聯絡 客戶支援

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

S Pichini et al.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 820(1), 151-156 (2005-05-04)
A high-performance liquid chromatography (HPLC)-mass spectrometry (MS) assay, already validated for opiates and cocaine in meconium, has been re-applied for determination of m- and p-hydroxybenzoylecgonine, using nalorphine as the internal standard. Methodology included an initial extraction from the matrix by
L M Iwamoto et al.
Drug metabolism and disposition: the biological fate of chemicals, 28(3), 335-338 (2000-02-19)
Recently, meta-hydroxybenzoylecgonine (m-OH BE) was identified by gas chromatography-mass spectroscopy during quantitative analysis for cocaine. Identification of m-OH BE in addition to the routinely identified benzoylecgonine by gas chromatography-mass spectroscopy confirmatory assays may increase detection of cocaine-exposed infants and decrease
B W Steele et al.
Journal of analytical toxicology, 17(6), 348-352 (1993-10-01)
Meconium has been reported to be a more suitable specimen than maternal or neonatal urine for detecting fetal exposure to cocaine. In a study comparing various immunoassays with gas chromatography/mass spectrometry (GC/MS), several unexplained discrepancies among the assays were noted.
M A elSohly et al.
Clinics in laboratory medicine, 18(4), 699-704 (1999-01-19)
m-Hydroxybenzoylecgonine (m-OH-BE) and d3-m- hydroxybenzoylecgonine (d3-m-OH-BE) have been synthesized, and a GC/MS procedure with d3-m-OH-BE as internal standard has been developed. Among 24 human urine specimens that were positive for BE, all of them have shown detectable levels of m-OH-BE
K L Klette et al.
Journal of analytical toxicology, 24(7), 482-488 (2000-10-24)
Positive benzoylecgonine (BZE) urinalysis results are sometimes challenged in legal and administrative proceedings on the grounds that the presence of BZE is due to the addition of cocaine to the urine sample with subsequent in vitro hydrolysis to BZE. Consequently

Global Trade Item Number

庫存單位GTIN
H-017-1ML4061833661857

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務