跳轉至內容
Merck
全部照片(2)

Key Documents

GF43235120

foil, 1m coil, thickness 0.075mm, annealed, 99.2%

同義詞:

登入查看組織和合約定價


About This Item

經驗公式(希爾表示法):
Zr
CAS號碼:
分子量::
91.22
MDL號碼:
分類程式碼代碼:
12141751
PubChem物質ID:
NACRES:
NA.23

化驗

99.2%

形狀

foil

製造商/商標名

Goodfellow 432-351-20

電阻係數

40 μΩ-cm, 20°C

長度 × 厚度

1 m × 0.075 mm

bp

4377 °C (lit.)

mp

1852 °C (lit.)

密度

6.5 g/mL at 25 °C (lit.)

SMILES 字串

[Zr]

InChI

1S/Zr

InChI 密鑰

QCWXUUIWCKQGHC-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

一般說明

For updated SDS information please visit www.goodfellow.com.

法律資訊

Product of Goodfellow

儲存類別代碼

4.1B - Flammable solid hazardous materials

水污染物質分類(WGK)

nwg

閃點(°F)

Not applicable

閃點(°C)

Not applicable


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

抱歉,我們目前沒有在線上提供本產品的COA

如果您需要協助,請聯絡 客戶支援

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Daryoush Afzali et al.
Environmental monitoring and assessment, 186(6), 3523-3529 (2014-02-04)
In this study, a ternary Zr(IV) system with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) and fluoride was chosen on the basis of dispersive liquid-liquid microextraction method. Zirconium was extracted into the fine droplets of dichlorobenzene as extracting solvent. These drops dispersed as a cloud
Muhammad Shahid et al.
Reviews of environmental contamination and toxicology, 221, 107-127 (2012-10-24)
Zirconium (Zr) is a transition metal that has both stable and radioactive isotopes.This metal has gained significant attention as a major pollutant of concern, partly because it has been prominent in the debate concerning the growing anthropogenic pressure on the
Oluwatayo F Ikotun et al.
Future medicinal chemistry, 3(5), 599-621 (2011-04-30)
Positron emission tomography, with its high sensitivity and resolution, is growing rapidly as an imaging technology for the diagnosis of many disease states. The success of this modality is reliant on instrumentation and the development of effective and novel targeted
Abnormal trace metals in man: zirconium.
H A Schroeder et al.
Journal of chronic diseases, 19(5), 573-586 (1966-05-01)
Joseph R Osborne et al.
The Journal of urology, 191(5), 1439-1445 (2013-10-19)
In this pilot study we explored the feasibility of (89)Zr labeled J591 monoclonal antibody positron emission tomography of localized prostate cancer. Before scheduled radical prostatectomy 11 patients were injected intravenously with (89)Zr-J591, followed 6 days later by whole body positron

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務