跳转至内容
Merck
  • Wide-range screening of psychoactive substances by FIA-HRMS: identification strategies.

Wide-range screening of psychoactive substances by FIA-HRMS: identification strategies.

Analytical and bioanalytical chemistry (2015-04-12)
Élida Alechaga, Encarnación Moyano, Maria Teresa Galceran
摘要

Recreational drugs (illicit drugs, human and veterinary medicines, legal highs, etc.) often contain lacing agents and adulterants which are not related to the main active ingredient. Serious side effects and even the death of the consumer have been related to the consumption of mixtures of psychoactive substances and/or adulterants, so it is important to know the actual composition of recreational drugs. In this work, a method based on flow injection analysis (FIA) coupled with high-resolution mass spectrometry (HRMS) is proposed for the fast identification of psychoactive substances in recreational drugs and legal highs. The FIA and HRMS working conditions were optimized in order to detect a wide range of psychoactive compounds. As most of the psychoactive substances are acid-base compounds, methanol-0.1 % aqueous formic acid (1:1 v/v) as a carrier solvent and electrospray in both positive ion mode and negative ion mode were used. Two data acquisition modes, full scan at high mass resolution (HRMS) and data-dependent tandem mass spectrometry (ddMS/HRMS) with a quadrupole-Orbitrap mass analyzer were used, resulting in sufficient selectivity for identification of the components of the samples. A custom-made database containing over 450 substances, including psychoactive compounds and common adulterants, was built to perform a high-throughput target and suspect screening. Moreover, online accurate mass databases and mass fragmenter software were used to identify unknowns. Some examples, selected among the analyzed samples of recreational drugs and legal highs using the FIA-HRMS(ddMS/HRMS) method developed, are discussed to illustrate the screening strategy used in this study. The results showed that many of the analyzed samples were adulterated, and in some cases the sample composition did not match that of the supposed marketed substance.

材料
货号
品牌
产品描述

Sigma-Aldrich
盐酸 溶液, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
盐酸, 36.5-38.0%, BioReagent, for molecular biology
Supelco
盐酸 溶液, volumetric, 0.1 M HCl (0.1N), endotoxin free
Sigma-Aldrich
利多卡因, powder
Sigma-Aldrich
咖啡因, anhydrous, 99%, FCC, FG
Sigma-Aldrich
苯佐卡因, ≥99% (HPLC)
Sigma-Aldrich
非那西丁, ≥98.0% (HPLC)
Sigma-Aldrich
盐酸 溶液, ~6 M in H2O, for amino acid analysis
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
氯化氢 溶液, 3 M in cyclopentyl methyl ether (CPME)
Sigma-Aldrich
咖啡因, powder, ReagentPlus®
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
甲酸, ≥95%, FCC, FG
Sigma-Aldrich
盐酸 溶液, 32 wt. % in H2O, FCC
Supelco
咖啡因标准液 溶液, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
乙腈, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
4-氨基苯甲酸乙酯, 98%
Sigma-Aldrich
利多卡因, analytical standard
Supelco
利多卡因标准液 溶液, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
(−)-Levamisole hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
甲醇, NMR reference standard
Sigma-Aldrich
咖啡因, Sigma Reference Standard, vial of 250 mg
Sigma-Aldrich
甲醇-12C, 99.95 atom % 12C
Sigma-Aldrich
咖啡因, meets USP testing specifications, anhydrous
Sigma-Aldrich
咖啡因, BioXtra
Sigma-Aldrich
乙腈 溶液, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
甲醇 溶液, (Methanol:Dimethyl sulfoxide 1:1 (v/v))