跳转至内容
Merck
  • A robust method for quantification of volatile compounds within and between vintages using headspace-solid-phase micro-extraction coupled with GC-MS--application on Semillon wines.

A robust method for quantification of volatile compounds within and between vintages using headspace-solid-phase micro-extraction coupled with GC-MS--application on Semillon wines.

Analytica chimica acta (2010-01-28)
Laure Rebière, Andrew C Clark, Leigh M Schmidtke, Paul D Prenzler, Geoffrey R Scollary
摘要

A headspace-solid-phase micro-extraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) method has been developed to quantify a range of volatile compounds in Hunter Valley Semillon wines. The fibre selected for the method was a 50/30 microm divinylbenzene/carboxen/polydimethylsiloxane fibre, a three-phase fibre that allows extraction and desorption of a wide range of volatile compounds of different chemical functionalities and polarities. Four internal standards, methyl isobutyl ketone, n-dodecane, 4-methyl-2-pentanol and ethyl nonanoate were used to monitor the SPME fibre extraction efficiency and integrity. Fibre integrity was monitored by plotting the ratio of the peak area for each internal standard divided by the sum of the peak area for all internal standards as a function of analysis number. The advantage of using four internal standards for better quality control of the fibre integrity is described. The identity of twenty-one volatile compounds was ascertained by comparison of their chemical characteristics (retention indices, mass spectra) with reference compounds using two columns of different polarities. Quantification was achieved using calibration curves constructed for each compound with linear regression equations having correlation coefficients (R(2)) ranging from 0.9717 to 0.9999. The method was applied to two Semillon wines (recent vintage and aged) representative of the Hunter Valley styles. As is typical of white wines, 3-methyl-1-butanol was quantified as the most concentrated volatile compound (83 and 66 mg L(-1) for the 2006 and the 1996 wines, respectively). The study highlights the use of well-defined procedures to ensure integrity of quantitative data where several fibres may be required during an extended study over one or more vintages.

材料
货号
品牌
产品描述

Supelco
SPME 纤维组件二乙烯基苯/羧基/聚二甲基硅氧烷 (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
SPME 纤维组件二乙烯基苯/羧基/聚二甲基硅氧烷 (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPME 纤维组件二乙烯基苯/羧基/聚二甲基硅氧烷 (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
SPME 纤维组件二乙烯基苯/羧基/聚二甲基硅氧烷 (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
ORBO Carboxen-564 管, W,F,F separators, O.D. × L 6 mm × 75 mm, pkg of 25 ea, for analyte group MEK (methylethyl ketone)
Supelco
SPME 纤维组件二乙烯基苯/羧基/聚二甲基硅氧烷 (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
ORBO-78 400/200mg,每包 25 支, W,W,W separators, O.D. × L 6 mm × 110 mm, pkg of 25 ea
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
Carbopack®吸附剂, matrix Carboxen® 1000, 60-80 mesh, bottle of 10 g
Supelco
Carboxen®1010 多孔层壁涂开管柱, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Carboxen® 1006 多孔层壁涂开管柱, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
聚丙烯酸酯 (PA) 固相微萃取萃取头, df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
Carboxen®1010 多孔层壁涂开管柱, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
SPME固相微萃取萃取头 Carboxen/聚二甲基硅氧烷 (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
SPME 纤维组件聚二甲基硅氧烷 (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
SPME固相微萃取萃取头,二甲基硅氧烷/二乙烯基苯(PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
固相微萃取 StableFlex 萃取头组合套件, for use with manual holder