跳转至内容
Merck

MSCAL5

Supelco

ProteoMass LTQ/FT-Hybrid ESI Pos. Mode Cal Mix

登录查看公司和协议定价


About This Item

分類程式碼代碼:
41116107
NACRES:
NA.24

產品線

ProteoMass

CofA

current certificate can be downloaded

包裝

pkg of 1 × 10 mL

儲存條件

protect from light

濃度

(varied conc.)

技術

mass spectrometry (MS): suitable

格式

multi-component solution

運輸包裝

dry ice

儲存溫度

−20°C

正在寻找类似产品? 访问 产品对比指南

一般說明

The ProteoMass ESI Calibration Kit for LTQ based Hybrids, positive ion mode calibration solution, enables calibration of Thermo Scientific hybrid instruments equipped with ESI source in positive ion mode. It covers a mass range from m/z 138 to m/z 1822, and is therefore usable for calibrations between m/z 50 and 2000.

應用

ProteoMass LTQ/FT-hybrid ESI Pos. mode cal mix has been used as a calibration standard for the mass spectrometric analysis of serum samples of patients affected by mugwort pollen allergy induced by pollen extract of Artemisia vulgaris.

特點和優勢

Discover the Advantages for Yourself!
  • Ready-to-use
  • Developed and qualified specifically for use with the LTQ based Thermo Scientific hybrid instruments (LTQ FT, LTQ FT Ultra, and LTQ Orbitrap series) with ESI source and Thermo Scientific Exactive
  • Conveniently packaged, freeing you from time consuming mixing and dilution steps, allowing you to focus on the acquistion of quality data

法律資訊

6538 is a trademark of American Type Culture Collection
ProteoMass is a trademark of Sigma-Aldrich Co. LLC

訊號詞

Danger

危險分類

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Eye Irrit. 2 - Flam. Liq. 2 - STOT SE 1

標靶器官

Eyes,Central nervous system

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 2

閃點(°F)

42.1 °F - closed cup

閃點(°C)

5.6 °C - closed cup


Choose from one of the most recent versions:

分析证书(COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

D Apostolovic et al.
Scientific reports, 7(1), 5201-5201 (2017-07-14)
The mammalian carbohydrate galactose-α1,3-galactose (α-Gal) causes a novel form of food allergy, red meat allergy, where patients experience severe allergic reactions several hours after red meat consumption. Here we explored gastric digestion of α-Gal glycoproteins using an in vitro model.
High-resolution mass spectrometry analysis of secondary organic aerosol generated by ozonolysis of isoprene.
Nguyen, T.B., et al.
Atmospheric Environment, 44(8), 1032-1042 (2010)
H Gallart-Ayala et al.
Rapid communications in mass spectrometry : RCM, 25(20), 3161-3166 (2011-09-29)
Benzophenone (BP) is one of the many contaminants reported as present in foodstuffs due to its migration from food packaging materials. Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is acknowledged in the literature as the method of choice for this analysis. However
Towards data acquisition throughput increase in Fourier transform mass spectrometry of proteins using double frequency measurements.
Vorobyev, A., et al.
International Journal of Mass Spectrometry and Ion Processes, 306(2-3), 227-231 (2011)
Jérôme Laparre et al.
Analytica chimica acta, 951, 99-107 (2016-12-22)
Urine stability during storage is essential in metabolomics to avoid misleading conclusions or erroneous interpretations. Facing the lack of comprehensive studies on urine metabolome stability, the present work performed a follow-up of potential modifications in urinary chemical profile using LC-HRMS

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门