ligand
recombinant protein A (E. coli)
製造商/商標名
Cytiva 28-9269-73
基質
highly cross-linked agarose
cleaning
2-12
工作範圍
3-10
一般說明
Determined at 10% breakthrough by frontal analysis at a mobile phase velocity of 500 cm/h in a column with a bed height of 20 cm.
HiScreen™ MabSelect™ is prepacked with MabSelect™ and is part of the process development platform available from Cytiva. The columns are an excellent choice for method optimization and parameter screening for capture of monoclonal antibodies (MAbs).
pH below 3 is sometimes required to elute strongly bound IgG species. However, protein ligands may hydrolyze at very low pH.
應用
The small column volume of 4.7 mL and bed height of 10 cm make HiScreen™ columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, since the 10 cm bed height gives enough residence time and the results can then serve as basis for linear process scale-up.
If necessary, two columns can easily be connected in series to give a bed height of 20 cm.
Media prepacked in HiScreen™ MabSelect™ columns are also available in other formats and as bulk packs, which makes it possible to use the same media for development work, pilot studies, and routine production.
If necessary, two columns can easily be connected in series to give a bed height of 20 cm.
Media prepacked in HiScreen™ MabSelect™ columns are also available in other formats and as bulk packs, which makes it possible to use the same media for development work, pilot studies, and routine production.
特點和優勢
- MabSelect™ is a BioProcess medium for capture of MAbs from large sample volumes.
- Prepacked, ready-to-use columns for convenient process development.
- 10 cm bed height of HiScreen™ columns is designed to allow method optimization and parameter screening.
- Easily connected in series to achieve 20 cm bed height.
- Small bed volume gives fast results and minimal sample/buffer consumption.
- Reproducible results, scalable to BioProcess columns packed with the same chromatography media using the same linear fluid velocity.
儲存和穩定性
Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
分析報告
To view the Certificate of Analysis for this product, please visit www.cytiva.com.
法律資訊
HiScreen is a trademark of Cytiva
MabSelect is a trademark of Cytiva
訊號詞
Warning
危險聲明
儲存類別代碼
3 - Flammable liquids
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门