跳转至内容
Merck

91490

Supelco

十三烷

analytical standard

登录查看公司和协议定价


About This Item

线性分子式:
CH3(CH2)11CH3
CAS号:
分子量:
184.36
Beilstein:
1733089
EC號碼:
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:
NACRES:
NA.24

等級

analytical standard

品質等級

蒸汽密度

6.4 (vs air)

蒸汽壓力

1 mmHg ( 59.4 °C)

化驗

≥99.5% (GC)

儲存期限

limited shelf life, expiry date on the label

技術

HPLC: suitable
gas chromatography (GC): suitable

折射率

n20/D 1.425 (lit.)
n20/D 1.426

bp

110-112 °C/12 mmHg (lit.)
234 °C (lit.)

mp

−6-−4 °C (lit.)

密度

0.756 g/mL at 25 °C (lit.)

應用

petroleum

形式

neat

SMILES 字串

CCCCCCCCCCCCC

InChI

1S/C13H28/c1-3-5-7-9-11-13-12-10-8-6-4-2/h3-13H2,1-2H3

InChI 密鑰

IIYFAKIEWZDVMP-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

應用

在用气相色谱法 (GLC) 分析六-1,5-二烯脱氢硅烷化得到的二乙基 [(1 E )-1,5-二烯基] 甲基硅烷和二乙基 [(1 E ,4 E )-1,4-二烯基] 甲基硅烷的异构比时,可使用十三烷作为内标。
有关合适仪器技术的更多信息,请参考产品分析证书。如需进一步支持,请联系技术服务部门。

象形圖

Health hazard

訊號詞

Danger

危險聲明

危險分類

Asp. Tox. 1

安全危害

儲存類別代碼

10 - Combustible liquids

水污染物質分類(WGK)

WGK 1

閃點(°F)

174.2 °F

閃點(°C)

79 °C

個人防護裝備

Eyeshields, Gloves, type ABEK (EN14387) respirator filter


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

其他客户在看

Slide 1 of 3

1 of 3

Adolfsson H, et al. et al.
Science of Synthesis: Houben-Weyl Methods of Molecular Transformations, 4 (2014)
Ash M et al.
Handbook of Green Chemicals (2004)
Anil Kumar Mishra et al.
Journal of drug targeting, 12(9-10), 559-567 (2004-12-29)
The purpose of this study was to obtain the convenient, synthetically useful bifunctional chelating agent, 6-(4-isothiocyanatobenzyl)-5,7-dioxo-1,11-(carboxymethyl)-1,4,8,11-tetraazacyclotridecane, and to apply it to stable (99m)Tc-labelling of monoclonal antibodies (mAbs). The chelate was synthesised by reaction of nitrobenzyl malonate and triethylenetetramine followed by
Aurora J Cruz Cabeza et al.
Chemical communications (Cambridge, England), (16)(16), 1600-1602 (2007-05-29)
We report on experimental and theoretical evidence for solvent inclusion in form II carbamazepine (R3) and discuss the implications for the formation and stability of this form.
Elena S Chernetsova et al.
Journal of chromatography. A, 1071(1-2), 55-58 (2005-05-04)
The influence of oxygen content in helium on the accuracy of nc/nH ratio determination for model mixtures of aliphatic and polyaromatic hydrocarbons and polychlorinated biphenyls was studied. The best accuracy was achieved at the oxygen content ca. 9%, which was

实验方案

Complete workflow for the comprehensive analysis of terpenes in cannabis

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门