跳转至内容
Merck

46264

Sigma-Aldrich

二茂铁甲酸

purum, ≥96%

别名:

二茂铁羧酸

登录查看公司和协议定价


About This Item

经验公式(希尔记法):
C11H10FeO2
CAS号:
分子量:
230.04
EC號碼:
MDL號碼:
分類程式碼代碼:
12352300
PubChem物質ID:
NACRES:
NA.22

等級

purum

品質等級

化驗

≥96%

反應適用性

core: iron
reagent type: catalyst

mp

210 °C (dec.) (lit.)

SMILES 字串

[Fe].[CH]1[CH][CH][CH][CH]1.OC(=O)[C]2[CH][CH][CH][CH]2

InChI

1S/C6H5O2.C5H5.Fe/c7-6(8)5-3-1-2-4-5;1-2-4-5-3-1;/h1-4H,(H,7,8);1-5H;

InChI 密鑰

VUJLGCHOGQEAED-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

一般說明

Ferrocene carboxylic acid (FCCa) is an organometallic compound comprised of a ferrocene core with a carboxylic acid functional group. It is used as a mediator in electrocatalytic oxidation. Due to its excellent redox properties, it is widely used in electrochemistry, redox probes, and peptide chain modifications. In addition, a direct cross-coupling reaction was explored using ferrocenecarboxylic acid and alkenes.

應用

Ferrocene carboxylic acid can be used as a:
  • Starting material in the synthesize of ferrocene-guanine conjugates.
  • Redox mediator in electrochemical-chemical-chemical (ECC) redox cycling.

儲存類別代碼

11 - Combustible Solids

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable

個人防護裝備

Eyeshields, Gloves, type N95 (US)


从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Huilan Su et al.
Biosensors & bioelectronics, 26(11), 4601-4604 (2011-05-31)
A multiple amplification immunoassay was proposed to detect alpha-fetoprotein (AFP), which was based on ferrocenemonocarboxylic-HRP conjugated on Pt nanoparticles as labels for rolling circle amplification (RCA). Firstly, the capture antibody (anti-AFP) was immobilized on glass carbon electrode (GCE) deposited nano-sized
Xuan-Hung Pham et al.
Analytica chimica acta, 671(1-2), 36-40 (2010-06-15)
We developed glucose biosensing electrodes using single-walled carbon nanotube (SWCNT) films on flexible, transparent poly(ethylene terephthalate). The homogeneous SWCNT films were fabricated by a vacuum filtration method, and the averaged resistivity and transparency of the fabricated flexible SWCNT films were
Latif Elci et al.
Talanta, 85(1), 551-555 (2011-06-08)
Solid-phase extraction (SPE) followed by derivatization and gas chromatography-atomic emission detection (GC-AED) was evaluated for the determination of five chlorophenols (CPs) in water samples. The derivatization was based on the esterification of phenolic compounds with ferrocenecarboxylic acid. The determination of
Beatriz Alonso et al.
Chemical communications (Cambridge, England), (16)(16), 1778-1779 (2002-08-29)
A new series of dendrimers with poly(propylene imine) backbones and 4, 8, 16, or 32 peripheral ferrocenyl-urea groups were prepared and characterized; their voltammetric behavior in DMSO solution was very sensitive to the presence of hydrogenphosphate anions at submillimolar concentration
Jean Chrysostome Ndamanisha et al.
Biosensors & bioelectronics, 23(11), 1680-1685 (2008-03-15)
Ordered mesoporous carbon (OMC) functionalized with ferrocenecarboxylic acid (Fc) was used to modify the glassy carbon (GC) electrode. The characterization of OMC-Fc shows that, after anchoring ferrocene on the mesoporous, ordered mesostructure of the material (OMC-Fc) remains intact and Fc

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门