跳转至内容
Merck

21193

Supelco

钙离子载体 II

Selectophore, function tested

别名:

N , N , N ′,N四 [环己基] 二乙醇酸二酰胺, N , N , N ′,N四环已基-3-氧杂戊二酰胺, ETH 129

登录查看公司和协议定价


About This Item

经验公式(希尔记法):
C28H48N2O3
CAS号:
分子量:
460.69
Beilstein:
6491651
MDL號碼:
分類程式碼代碼:
26111700
PubChem物質ID:
NACRES:
NB.61

等級

for ion-selective electrodes

品質等級

產品線

Selectophore

形狀

solid

品質

function tested

SMILES 字串

O=C(COCC(=O)N(C1CCCCC1)C2CCCCC2)N(C3CCCCC3)C4CCCCC4

InChI

1S/C28H48N2O3/c31-27(29(23-13-5-1-6-14-23)24-15-7-2-8-16-24)21-33-22-28(32)30(25-17-9-3-10-18-25)26-19-11-4-12-20-26/h23-26H,1-22H2

InChI 密鑰

URAUKAJXWWFQSU-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

一般說明

请访问我们的 传感器应用页面 以了解更多信息。

應用

精选应用实例
适用于细胞内钙测定
采用钙离子载体 (ETH 129) 制备了用于测定解离常数 (K d ) 的钙离子选择性微电极。
用于制作钙离子选择电极的亲脂性离子载体,该离子电极的检测限可以达到亚钠摩尔级。高效钙离子载体;在膜中对 Ca2+ 的选择性大约为 Mg2+ 的 104 倍。

包裝

无底玻璃瓶。内含物在插入的融合锥体内。

法律資訊

Selectophore is a trademark of Merck KGaA, Darmstadt, Germany

儲存類別代碼

11 - Combustible Solids

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable

個人防護裝備

dust mask type N95 (US), Eyeshields, Gloves


从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

其他客户在看

G Prestipino et al.
Analytical biochemistry, 210(1), 119-122 (1993-04-01)
We have investigated the ability of the neutral ionophore ETH 129 to translocate Ca2+ across artificial and biological membranes. ETH 129 induces Ca2+ transport across planar lipid bilayer. The zero-current membrane potential in a gradient of Ca2+ concentration exhibits Nernst
Iwona Bedlechowicz-Sliwakowska et al.
Analytical and bioanalytical chemistry, 385(8), 1477-1482 (2006-07-19)
In this work, ion-selective electrodes for calcium ion were investigated. Two ionophores were used in the membranes: ETH 1001 and ETH 129. An internal filling solution buffered for primary ion was used that allowed the lower detection limit to be
N Abramova et al.
Talanta, 113, 31-35 (2013-05-28)
An analytical system based on ion-selective field effect transistors (ISFETs) with Ca(2+) ion selective photocurable membranes is developed to offer a semiautomatic analysis of serum calcium concentration of ruminants. Optimisation of ion-sensitive membrane composition containing different copolymerised plasticizers was performed
Yi Yuan et al.
Analytical chemistry, 76(18), 5570-5578 (2004-09-15)
Chronoamperometry was carried out at liquid/liquid interfaces supported at the tip of micropipet electrodes for direct determination of the diffusion coefficient of a species in the outer solution. The diffusion coefficient was used for subsequent determination of the transferred charges
Mariya V Kovaleva et al.
Journal of bioenergetics and biomembranes, 41(3), 239-249 (2009-07-18)
In this study we used tightly-coupled mitochondria from Yarrowia lipolytica and Dipodascus (Endomyces) magnusii yeasts, possessing a respiratory chain with the usual three points of energy conservation. High-amplitude swelling and collapse of the membrane potential were used as parameters for

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门