推荐产品
材料
acrylic
polypropylene
silica filter aid
品質等級
特點
hydrophilic
製造商/商標名
Millistak+®
參數
2.1 bar max. differential pressure (30 psid) at 25 °C (Forward)
30 psid max. differential pressure (2.1 bar) at 37 °C (Reverse)
30 psid max. differential pressure (2.1 bar) at 4 °C (Forward)
30 psid max. inlet pressure (2.1 bar) at 25 °C
高度
140 mm
5.5 in. (14 cm)
長度
8.6 in. (22 cm)
過濾面積
0.014 m2
雜質
<0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
輸入
sample type liquid
傅導性
3.64-10.5 μS/cm at 25 °C (product water)
過濾器等級
C0SP
正在寻找类似产品? 访问 产品对比指南
相关类别
一般說明
The Millistak+® HC Pro Pod Depth Filter (high capacity synthetic media) is a synthetic depth filter providing a cleaner and more consistent depth filtration media over current diatomaceous earth (DE) and cellulose (CE) based filter offerings. This unit, featured in a Lab Scale Pod format with a C0SP media grade, supports primary and secondary clarification as well as downstream filtration applications.
應用
Primary and Secondary Clarification (direct harvest; centrate)
特點和優勢
Synthetic materials of construction
Lot to lot consistency for successful development and implementation of robust clarification processes
Depth filter media formulation & design
Disposable Pod device
- Reduce TOC extractables and pre-use flush volume requirements by 50%
- No beta glucans to interfere with limulous amoebocyte lysate (LAL) testing for bacterial endotoxins
Lot to lot consistency for successful development and implementation of robust clarification processes
Depth filter media formulation & design
- Provide as much as two times the filtration capacity with equivalent filter retention properties over commercial DE-based benchmarks
- Improved HCP impurity clearance
Disposable Pod device
- Flexible, modular format offers scalability from 5 to 12,000 liters or more
- Robust device format; easy to use and set up
規格
Filter Grade: C0SP
Trace metals were measured post pure water flush of 50 L/m2 of surface area and 24-hour static soak in pure water. Values based on average of metals extractibles data from three separate uPod device lots. The analysis was made by ICP-MS. The devices were not autoclaved.
準備報告
Sterilization Method
1 autoclave cycle of 60 min @ 123 ºC, filtration performance may be impacted. Recommended for post use contamination only.
1 autoclave cycle of 60 min @ 123 ºC, filtration performance may be impacted. Recommended for post use contamination only.
分析報告
Product Water Conductivity at 25°C: post autoclave (1 cycle of 60 minutes at 123 °C) and pure water flush of 10 liter per ft2 (100 L/m2 of media surface area
法律資訊
MILLISTAK+ is a registered trademark of Merck KGaA, Darmstadt, Germany
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门