推荐产品
等級
certified reference material
品質等級
形狀
liquid
特點
Snap-N-Spike®/Snap-N-Shoot®
包裝
ampule of 1 mL
製造商/商標名
Cerilliant®
drug control
Narcotic Licence Schedule E (Switzerland); psicótropo (Spain); Decreto Lei 15/93: Tabela IIA (Portugal)
濃度
1.0 mg/mL in methanol (as free base)
技術
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
應用
forensics and toxicology
形式
single component solution
儲存溫度
−20°C
InChI
1S/C16H21NO3.ClH/c1-2-5-13(17-8-3-4-9-17)16(18)12-6-7-14-15(10-12)20-11-19-14;/h6-7,10,13H,2-5,8-9,11H2,1H3;1H
InChI 密鑰
PYQZNWFQAMFAMT-UHFFFAOYSA-N
一般說明
應用
- MDPV HCl research chemical: Used to study the impact of synthetic cathinones on gut microbiota, providing insights into their broader physiological effects (Angoa-Pérez et al., 2023).
- Synthetic cathinones: Employed in forensic science for the detection and quantification of synthetic cathinones in hair, aiding in the analysis of drug abuse cases (Freni et al., 2019).
- Psychoactive substance study: Investigated for their effects on human behavior and mental health, contributing to a deeper understanding of substance use disorders (Lendoiro et al., 2017).
- Dopamine reuptake inhibitor: Researched for its potential mechanisms as a dopamine reuptake inhibitor, providing valuable data for the development of therapeutic agents for neuropsychiatric disorders (Wood et al., 2015).
法律資訊
相關產品
訊號詞
Danger
危險分類
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
標靶器官
Eyes,Central nervous system
儲存類別代碼
3 - Flammable liquids
水污染物質分類(WGK)
WGK 2
閃點(°F)
49.5 °F - closed cup
閃點(°C)
9.7 °C - closed cup
商品
The combination of ion-exchange SPE with the HILIC HPLC separation provides a novel approach for the testing of problematic bath salt compounds.
The combination of ion-exchange SPE with the HILIC HPLC separation provides a novel approach for the testing of problematic bath salt compounds.
This article highlights the impact that sample matrix effects can have on LC/MS response and discusses two novel approaches to reduce it.
This article highlights the impact that sample matrix effects can have on LC/MS response and discusses two novel approaches to reduce it.
实验方案
Separation of 3,4-Methylenedioxypyrovalerone HCl (MDPV) solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; Buphedrone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; 3-Fluoromethcathinone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; Butylone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; Ethylone hydrochloride, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; 4-Fluoromethcathinone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; Mephedrone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; Methylone hydrochloride, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material; Methedrone hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material