推荐产品
品質等級
化驗
97%
形狀
powder
mp
145-148 °C (lit.)
官能基
bromo
carboxylic acid
SMILES 字串
OC(=O)c1c(Br)cc(Br)c(O)c1Br
InChI
1S/C7H3Br3O3/c8-2-1-3(9)6(11)5(10)4(2)7(12)13/h1,11H,(H,12,13)
InChI 密鑰
YDBHVMTTYXWHLI-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
一般說明
2,4,6-三溴-3-羟基苯甲酸(TBHBA)是一种用作结构单元的有机化合物。TBHBA 是一种测定血浆中高密度脂蛋白(HDL)游离胆固醇部分的酶比色试剂。
應用
- One-pot synthesis and nano-bio applications: Research described a one-pot bottom-up synthesis technique for a 2D graphene derivative, utilizing 2,4,6-Tribromo-3-hydroxybenzoic acid, demonstrating its applications in biomolecular recognition and nanozyme activities (Pandit and De, 2021).
訊號詞
Warning
危險分類
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
標靶器官
Respiratory system
儲存類別代碼
11 - Combustible Solids
水污染物質分類(WGK)
WGK 3
個人防護裝備
dust mask type N95 (US), Eyeshields, Gloves
Scandinavian journal of clinical and laboratory investigation, 48(1), 59-64 (1988-02-01)
A sensitive enzymatic method for the measurement of high density lipoprotein choline-containing phospholipids (HDL-pc) was adapted to a Cobas Bio Centrifugal Analyzer. The Boehringer Mannheim phospholipase D/choline oxidase/peroxidase reagent was modified by the inclusion of 2,4,6,-tribromo-3-hydroxybenzoic acid (TBHBA) which reacts
The American journal of clinical nutrition, 101(4), 725-732 (2015-04-04)
Elevated concentrations of serum uric acid are associated with increased risk of gout and renal and cardiovascular diseases. Genetic studies in adults have consistently identified associations of solute carrier family 2, member 9 (SLC2A9), polymorphisms with variation in serum uric
Annals of clinical biochemistry, 21 ( Pt 5), 430-433 (1984-09-01)
The Boehringer one-component high-performance cholesterol oxidase reagent has been modified by the inclusion of 2,4,6-tribromo-3-hydroxybenzoic acid (TBHBA) to give a fourfold increase in sensitivity to a molar absorbance of approximately equal to 29,000 with respect to cholesterol. The resulting reagent
Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie, 25(9), 583-587 (1987-09-01)
A sensitive fixed-time kinetic enzymatic method for the measurement of high density lipoprotein cholesterol is described, as adapted for the Cobas Bio centrifugal analyser (Hoffmann LaRoche). The Boehringer Mannheim cholesterol esterase/cholesterol oxidase/peroxidase/3,4-dichlorophenol kinetic reagent was modified by the inclusion of
Clinical chemistry, 34(9), 1799-1804 (1988-09-01)
A highly sensitive enzymic colorimetric reagent is described for determination of the free cholesterol fraction of high-density lipoprotein (HDL), which represents about 20% of the total cholesterol content of this lipoprotein. For greater sensitivity with respect to cholesterol, I used
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门