跳转至内容
Merck

266299

Sigma-Aldrich

powder, ≥99% trace metals basis, <45 μm

别名:

Cd

登录查看公司和协议定价


About This Item

经验公式(希尔记法):
Cr
CAS号:
分子量:
52.00
EC號碼:
MDL號碼:
分類程式碼代碼:
12161600
PubChem物質ID:
NACRES:
NA.22

品質等級

化驗

≥99% trace metals basis

形狀

powder

反應適用性

core: chromium
reagent type: catalyst

電阻係數

12.7 μΩ-cm, 20°C

粒徑

<45 μm

bp

2672 °C (lit.)

mp

1857 °C (lit.)

密度

7.14 g/mL at 25 °C (lit.)

SMILES 字串

[Cr]

InChI

1S/Cr

InChI 密鑰

VYZAMTAEIAYCRO-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

一般說明

铬是化学合成中广泛使用的催化剂。它还用于制备其他基于铬的化合物。

應用

铬(Cr)粉末可用于制备活性碳中基于铬的为纳米多孔金属有机框架。这种复合材料可作为吸附剂,用于从水中去除新兴关注的污染物(CEC)。

儲存類別代碼

11 - Combustible Solids

水污染物質分類(WGK)

nwg

閃點(°F)

Not applicable

閃點(°C)

Not applicable

個人防護裝備

Eyeshields, Gloves, type N95 (US)


从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

J A J Vanoirbeek et al.
Journal of toxicology and environmental health. Part A, 66(4), 393-409 (2003-01-30)
Chromium-based catalysts are used for the synthesis of polyethylene, but little is known about the hazard and biomonitoring possibilities of this type of chromium for workers who may be occupationally exposed to such compounds. Therefore, the bioavailability and toxicokinetics of
B Seifert et al.
Journal of exposure analysis and environmental epidemiology, 10(2), 103-114 (2000-05-03)
The German Environmental Survey (GerES) is a large-scale population study which has repeatedly been carried out in Germany. GerES I was conducted in 1985/1986 followed by GerES IIa in 1990/1991 (West Germany) and GerES IIb in 1991/1992 (East Germany). GerES
Feng Liu et al.
Scientific reports, 3, 1554-1554 (2013-03-28)
In conventional photostimulable storage phosphors, the optical information written by x-ray or ultraviolet irradiation is usually read out as a visible photostimulated luminescence (PSL) signal under the stimulation of a low-energy light with appropriate wavelength. Unlike the transient PSL, here
A J Hart et al.
The Journal of bone and joint surgery. American volume, 95(8), 678-685 (2013-04-19)
Determining the relationship between clinical factors and engineering analysis of retrieved hip implants can help our understanding of the mechanism of device failure. This is particularly important for metal-on-metal hip arthroplasties because the most common cause of failure is unexplained.
Carola Lidén et al.
Contact dermatitis, 54(5), 233-238 (2006-05-13)
There is a great need to accurately assess skin exposure to contact allergens. We have developed a technique for assessment of skin exposure to nickel, chromium and cobalt using acid wipe sampling by cellulose wipes with 1% nitric acid. Chemical

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门