Saltar al contenido
Merck

Tissue-smashing based ultra-rapid extraction of chemical constituents in herbal medicines.

Journal of pharmaceutical and biomedical analysis (2014-04-02)
Yong Fan, Chen-Pu Yan, Cheng Chen, Kwok-Fai So, Ping Li, Lian-Wen Qi
RESUMEN

Sample extraction is the first challenge in analysis of herbal medicines (HMs). Numerous methods have been developed to improve extraction efficiency, use less solvent and short time. In this work, a tissue-smashing based ultra-rapid extraction (TSURE) method has been proposed through the designed particle crushing, drastic stir, and dynamic molecular permeation at normal temperature. Factors in TSURE like extraction time, volts, and solvents were optimized for extraction efficiency of salvianolic acid B, cryptotanshinone, and tanshinone IIA from Salvia miltiorrhiza. The TSURE method was validated in terms of repeatability (RSD<2.2%) and extraction recoveries (93-106% with RSD<5.0%). TSURE showed a comparable extraction efficiency to conventional heat reflux extraction (HRE) and better than ultrasonic assisted extraction (UAE). The extraction time was about 2.0-3.0 min for TSURE, 60 times faster than the performance of HRE and 20 times faster than UAE. Microscopic analysis showed that the Krummbein diameter of plant particles after extraction were about 600-1200 μm for HRE and UAE, and decreased to 50-80 μm for TSURE. Subsequently, the developed TSURE was applied to high-throughput extraction of 19 S. miltiorrhiza samples collected in different regions of China. Besides, application of TSURE to other herbal medicines was also investigated, including Panax quinquefolius and Lonicera japonica. TSURE method provided an ultra-rapid and promising alternation for extraction of ingredients in herbal medicines, and can be extended to pharmaceutics, foods and cosmetics.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrilo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acetonitrilo, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrilo, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Chlorogenic acid, ≥95% (titration)
Sigma-Aldrich
Acetonitrilo, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
Acetonitrilo solution, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrilo, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Acetonitrilo, biotech. grade, ≥99.93%
Sigma-Aldrich
Acetonitrilo solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Supelco
Acetonitrilo, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetonitrilo, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrilo, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acetonitrilo, suitable for DNA synthesis, ≥99.9% (GC)
Chlorogenic acid, primary reference standard
Supelco
Acetonitrilo, analytical standard
Sigma-Aldrich
Salvianolic acid B, ≥94% (HPLC)
USP
Acetonitrilo solution, United States Pharmacopeia (USP) Reference Standard
Chlorogenic acid, European Pharmacopoeia (EP) Reference Standard
Supelco
Acetonitrilo, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Acetonitrilo, suitable for HPLC, gradient grade, ≥99.9% (GC)
Sigma-Aldrich
Acetonitrilo solution, contains 10.0% acetone, 0.05% formic acid, 40.0% 2-propanol
Sigma-Aldrich
Acetonitrilo, ≥99.5%, ACS reagent
Sigma-Aldrich
Acetonitrilo solution, contains 0.05 % (w/v) ammonium formate, 5 % (v/v) water, 0.1 % (v/v) formic acid, suitable for HPLC
Supelco
Salvianolic acid B, analytical standard
Sigma-Aldrich
Acetonitrilo solution, contains 0.05 % (v/v) trifluoroacetic acid
Salvianolic acid B, European Pharmacopoeia (EP) Reference Standard