GC Analysis of Pesticides in Avocado on SLB®-5ms (20 m x 0.18 mm I.D., 0.36 μm) after QuEChERS Cleanup using Supel QuE Z-Sep+, Fast GC Analysis

application for SPE, suitable for GC

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

technique(s)

gas chromatography (GC): suitable
solid phase extraction (SPE): suitable

test parameters

sample preparation: Dispersive (QuEChERS)
sample/matrix: Avocado spiked with pesticides at 20 ng/g
extraction tube: Supel QuE Acetate extraction tube (55234-U)
extraction process: add 25 mL of acetonitrile; shake for 1 minute; add contents of Supel QuE acetate extraction tube; shake immediately for 1 minute; centrifuge at 3200 rpm for 5 minutes
clean-up tube: Supel Que Z-Sep+ cleanup tube (55296-U)
clean-up process: transfer 3 mL of the acetonitrile layer into a Supel Que Z-Sep+ cleanup tube; shake for 1 minute; centrifuge at 3400 rpm for 3 minutes; draw off supernatant for LVI-GCMS analysis
column: SLB-5ms, 20 m x 0.18 mm I.D., 0.36 μm (28576-U)
oven: 70 °C (2 min), 15 °C/min to 325 °C (6 min)
inj. temp.: 60 °C (0.28 min), 600 °C/min to 325 °C (5 min)
detector: MSD
MSD interface: 330 °C
carrier gas: helium, 1 mL/min, constant
injection: PTV solvent vent; 10 μL, injection dispense speed 15000 μL/min
liner: 4 mm I.D. FocusLiner with taper
sample: pesticides spiked at 20 ng/g

suitability

application for SPE

application(s)

agriculture
food and beverages

Analysis Note

About this analysis: This application demonstrates the use of dispersive SPE for the extraction of pesticides from Avocado. Cleanup is achieved using Z-Sep + for fat removal. FInal analysis of the extracts was done by LVI-GC/MS SIM on an SLB-5ms column.

Legal Information

SLB is a registered trademark of Merck KGaA, Darmstadt, Germany
Supel is a trademark of Sigma-Aldrich Co. LLC

Analito

Descripción

    Trifluralin
    α-1,2,3,4,5,6-Hexachlorocyclohexane
    Hexachlorobenzene
    Dimethoate
    Simazine
    Pentachloronitrobenzene
    Lindane
    Heptachlor
    Malathion
    Metolachlor
    4,4′-DDT
    Methoxychlor
    Coumaphos
    Deltamethrin
    Ver todo (14)

SPE tube or plate

Referencia del producto
Descripción
Precios

Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

Lo sentimos, en este momento no disponemos de COAs para este producto en línea.

Si necesita más asistencia, póngase en contacto con Atención al cliente

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico