Saltar al contenido
Merck

Z-003

Supelco

Zopiclone solution

1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula empírica (notación de Hill):
C17H17ClN6O3
Número de CAS:
Peso molecular:
388.81
EC Number:
UNSPSC Code:
41116107
NACRES:
NA.24

grade

certified reference material

form

liquid

feature

Snap-N-Spike®/Snap-N-Shoot®

packaging

ampule of 1 mL

manufacturer/tradename

Cerilliant®

concentration

1.0 mg/mL in acetonitrile

technique(s)

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

application(s)

clinical testing

format

single component solution

storage temp.

−20°C

SMILES string

C[NH+]1CCN(CC1)C(=O)OC2N(C(=O)c3nccnc23)c4ccc(Cl)cn4

InChI

1S/C17H17ClN6O3/c1-22-6-8-23(9-7-22)17(26)27-16-14-13(19-4-5-20-14)15(25)24(16)12-3-2-11(18)10-21-12/h2-5,10,16H,6-9H2,1H3/p+1

InChI key

GBBSUAFBMRNDJC-UHFFFAOYSA-O

General description

A certified solution standard suitable for use in LC/MS or GC/MS applications for clinical toxicology, forensic analysis, pharmaceutical research, or urine drug testing.  Zopiclone is a non-benzodiazepine hypnotic sold under the trade names Imovane® and ZImovane® and is prescribed for the treatment of insomnia.

Application

  • Zopiclone solution pharmacological research applications: Utilized in developing and validating analytical methods for detecting z-drugs in biological samples, enhancing forensic toxicology and clinical diagnostics (Chauhan et al., 2024).
  • Zopiclone as a GABA receptor modulator in biochemistry: Investigated for its role in drug-facilitated crimes, particularly its identification through presumptive spot tests, which is crucial for forensic analysis (Chauhan and Sharma, 2023).
  • Zopiclone solution for sleep disorder experimental studies: Analyzed for its effects on hyperlipidemic conditions in postmortem blood, contributing to forensic science and medical research (Elenstål et al., 2023).
  • Zopiclone liquid formulation stability in laboratory conditions: Reviewed for long-term medication use in insomnia treatments, providing essential data on clinical safety and efficacy (Zee et al., 2023).
  • Zopiclone in vitro receptor binding assays methodology: Employed in evaluating the toxicity of zopiclone impurities, supporting the development of safer pharmaceutical products (Yin et al., 2023).

Legal Information

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Imovane is a registered trademark of Sanofi-Aventis
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

Related product

pictograms

FlameExclamation mark

signalword

Danger

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2

Storage Class

3 - Flammable liquids

wgk_germany

WGK 2

flash_point_f

35.6 °F - closed cup

flash_point_c

2 °C - closed cup


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Judith Peacey et al.
The Journal of nervous and mental disease, 200(1), 83-87 (2012-01-03)
Adult patients (N = 100) being treated for acute psychiatric illness were interviewed about their sleep problems and attitudes toward available treatments. Most (74%) were using at least one prescribed psychotropic drug with hypnotic or sedative effects. Participants prescribed three
[Determination of zopiclone in serum by gas chromatographic method].
Zi-ru Cheng et al.
Zhonghua lao dong wei sheng zhi ye bing za zhi = Zhonghua laodong weisheng zhiyebing zazhi = Chinese journal of industrial hygiene and occupational diseases, 30(4), 314-315 (2012-07-19)
To breathe, perchance not to wake?
David M Rapoport
Journal of applied physiology (Bethesda, Md. : 1985), 112(2), 247-248 (2011-10-29)
Milena Araújo Tonon et al.
Analytical and bioanalytical chemistry, 405(1), 267-273 (2012-11-07)
A new high-performance liquid chromatographic method with triple quadrupole mass spectrometry detection was developed and validated for the quantification of zopiclone enantiomers in rat brain samples. Zopiclone enantiomers were resolved on a CHIRALPAK AD column with a mobile phase consisting
Nico J Diederich et al.
Journal of the neurological sciences, 314(1-2), 12-19 (2011-11-29)
Sleep symptoms in Parkinson's disease (PD) are frequent and have multifactorial and multilayered causes. Primary involvement of sleep/wake regulating centers in the brainstem, sleep problems caused by the nocturnal manifestation of motor and dysautonomic signs and medication-induced sleep problems are

Artículos

An rapid method for the siµLtaneous determination of the Z-drugs or sleep aids: zopiclone, zolpidem, and zaleplon is presented here. The need for greater analytical capacity and throughput for the analysis of sleep aid medicines (Z-drugs) in forensic toxicology laboratories can be met by the use of fast Ascentis Express 2.0 micron Fused Core UHPLC Columns.

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico