Saltar al contenido
Merck

651834

Sigma-Aldrich

Nichrome etchant

standard

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

MDL number:
UNSPSC Code:
12161700
NACRES:
NA.23

grade

standard

composition

volatiles, 85%

color

clear yellow-orange

bp

100 °C/1 atm

density

1.16 g/mL at 25 °C

General description

Nichrome etchant is a high purity etching system that is a mixture of ceric ammonium nitrate and nitric acid. It can be used to etch the nickel and chromium alloy.

Application

Ceric ammonium nitrate-based etchant. Etches Al, Cr, Cu, Ni, GaAs. Surface oxidizes Si, Ta/TaN. Etch rate of 50 Å/sec @ 40 °C. Etches cleanly with only a deionized water rinse needed.
Nichrome etchant is used in the fabrication of microheater patterns of polydimethyl siloxane (PDMS), silica (SiO2) and glass substrates, which can be further used in the fabrication of flow sensors. It may also be used to etch out nickel (Ni) from the electroplated Ni on amorphous silica wafers.
For use at room temperature or elevated temperature. Etches cleanly, eliminating need for an intermediate rinse.

Features and Benefits

Designed for etching nichrome thin films used in microelectronic applications. Compatible with both positive and negative photoresists and provides fine-line control with minimal undercutting. Filtered to 0.2 micron to remove particlulates and composed of semiconductor grade materials.

signalword

Danger

Hazard Classifications

Aquatic Chronic 2 - Eye Dam. 1 - Met. Corr. 1 - Ox. Liq. 2 - Skin Corr. 1B - Skin Sens. 1

supp_hazards

Storage Class

5.1B - Oxidizing hazardous materials

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Simulation and feasibility study of flow sensor on flexible polymer for healthcare application.
Maji D and Das S
IEEE Transactions on Bio-Medical Engineering, 60(12), 3298-3305 (2013)
Perfectly plastic flow in silica glass.
Kermouche G, et al.
Acta Materialia, 114(12), 146-153 (2016)

Protocolos

Negative Photoresist Procedure

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico