182478
Poly(tetrafluoroethylene)
powder, >40 μm particle size
Sinónimos:
Fluorinated polymer, Fluoropolymer, PTFE
Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización
About This Item
Productos recomendados
form
powder
Quality Level
particle size
>40 μm
transition temp
Tg 130 °C
Tm 327 °C
density
2 g/mL at 25 °C
SMILES string
F\C(F)=C(\F)F
¿Está buscando productos similares? Visita Guía de comparación de productos
Categorías relacionadas
General description
Poly(tetrafluoroethylene) (PTFE) is a stable fluoropolymer used in the field of coatings, thermal ceilings, supercapacitors, lubricators, bearings, and clinical applications.
Application
Poly(tetrafluoroethylene) can be used as a precursorto fabricate supercapacitors.
Features and Benefits
- Chemically and biologically inert
- Recyclable
- Able to resist enzymatic and microbiological attack
- Extremely low coefficient of friction
- Insulating and dielectric properties
Storage Class
11 - Combustible Solids
wgk_germany
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Eyeshields, Gloves, type N95 (US)
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Los clientes también vieron
Nature communications, 5, 5543-5543 (2014-11-22)
The synthesis of enantiopure molecules from achiral precursors without the need for pre-existing chirality is a major challenge associated with the origin of life. We here show that an enantiopure product can be obtained from achiral starting materials in a
The Journal of thoracic and cardiovascular surgery, 150(1), 152-157 (2015-03-15)
Robotically assisted cardiac surgery is an alternative to conventional, open-chest surgery. Although studies have been done on the clinical effect, morbidity, and mortality of robotically assisted atrial myxoma excision, few have addressed surgical outcomes, such as pain, quality of life
Anesthesiology, 122(1), 117-126 (2014-08-30)
Multicapillary column ion-mobility spectrometry (MCC-IMS) may identify volatile components in exhaled gas. The authors therefore used MCC-IMS to evaluate exhaled gas in a rat model of sepsis, inflammation, and hemorrhagic shock. Male Sprague-Dawley rats were anesthetized and ventilated via tracheostomy
Nature communications, 5, 5254-5254 (2014-10-17)
Despite recent progress in preparing numerous types of nanosheets, it remains a difficult challenge to assemble the tiny building blocks into functional macroscale architectures suitable for practical applications. Here we introduce a diffusion driven layer-by-layer assembly process and demonstrate its
Journal of the American College of Cardiology, 62(15), 1320-1327 (2013-07-09)
The hypothesis that endovascular treatment with covered stents has equal risks but higher efficacy than bare-metal stents (BMS) in long femoropopliteal artery disease was tested. Although endovascular treatment of short superficial femoral artery lesions revealed excellent results, efficacy in long
Artículos
Materials Issues in Polymer Electrolyte Membrane Fuel Cells
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico