Grade
reagent grade
제품 라인
Vetec™
분석
≥99%
형태
crystalline
pH
2.5-5.0 (25 °C, 213.3 g/L)
유용한 pH 범위
6.4-7.8
pKa(25 °C)
7.1
solubility
water: 0.5 g/mL, clear, colorless
SMILES string
OCCN(CCO)CCS(O)(=O)=O
InChI
1S/C6H15NO5S/c8-4-1-7(2-5-9)3-6-13(10,11)12/h8-9H,1-6H2,(H,10,11,12)
InChI key
AJTVSSFTXWNIRG-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
법적 정보
Vetec is a trademark of Merck KGaA, Darmstadt, Germany
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 10(12), 1449-1455 (2014-11-26)
Stent fracture is important because it may cause adverse events. The interventional cardiologist needs independent data to aid stent selection. Stent designers need data to improve stent design. We used a repetitive bend test to compare durability and fracture for
Circulation journal : official journal of the Japanese Circulation Society, 79(6), 1323-1331 (2015-04-07)
Coronary adventitia harbors a wide variety of components, such as inflammatory cells and vasa vasorum (VV). Adventitial VV initiates the development of coronary artery diseases as an outside-in supply route of inflammation. We have recently demonstrated that drug-eluting stent implantation
The journal of physical chemistry letters, 6(15), 2933-2937 (2015-08-13)
Colloidal CdSe quantum dot (QD) core ensembles were photodimmed and allowed to recover in the dark using ambient thermal energy at a range of temperatures. Nonlinear thermal recovery is well described by a stretched exponential function, and further analysis yields
Nano letters, 15(7), 4657-4663 (2015-06-24)
Noncrystalline semiconductor materials often exhibit hysteresis in charge transport measurements whose mechanism is largely unknown. Here we study the dynamics of charge injection and transport in PbS quantum dot (QD) monolayers in a field effect transistor (FET). Using Kelvin probe
International journal of cardiology, 186, 178-185 (2015-04-02)
Numerous studies have demonstrated an association between endothelial shear stress (ESS) and neointimal formation after stent implantation. However, the role of ESS on the composition of neointima and underlying plaque remains unclear. Patients recruited in the Comfortable AMI-IBIS 4 study
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.