추천 제품
기술
HPLC: suitable
검사 파라미터
column: Ascentis Express HILIC, 10 cm x 2.1 mm I.D., 2.7 μm particles (53939-U)
gradient: 5 mM ammonium formate in acetonitrile:water (90:10, v/v)
flow rate: 0.4 mL/min
column temp.: 35 °C
detector: TOF/MS
injection: 2 μL
sample: 300 ng/mL in acetonitrile
적합성
application for HPLC
응용 분야
forensics and toxicology
분석 메모
The fluoroamphetamines (FA) are a group of "designer" stimulant drugs in amphetamine family. The rapid LC/MS analysis of four members of the FA family on Ascentis Express HILIC is shown here. Cerilliant CRMs were used to ensure reliable MS identification and quantification.
법적 정보
Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany
분석물
설명
(±)-2-Fluoroamphetamine hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material, Cerilliant®
4-Fluoroamphetamine hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material, Cerilliant®
(±)-2-Fluoromethamphetamine hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material, Cerilliant®
(±)-4-Fluoromethamphetamine hydrochloride solution, 1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material, Cerilliant®
가장 최신 버전 중 하나를 선택하세요:
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.