Visiprep Large Volume Sampler

for use with 3 or 6 mL SPE tubes (includes 4 adapters)

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
12000000

material

PTFE frit

Agency

suitable for EPA 533

제품 라인

Visiprep

기술

solid phase extraction (SPE): suitable

응용 분야

food and beverages

호환성

for use with 3 or 6 mL SPE tubes (includes 4 adapters)
technique used for transfers 4 large volume samples

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

For continuous "hands off" direct transfer of multiple liquid samples

A Visiprep large volume sampler enables you to transfer low viscosity samples directly from any sample container to conventional solid phase extraction tubes on a Visiprep SPE vacuum manifold.

Two samplers are available. One sampler has three tube adapters compatible with 12mL, 20mL, or 60mL polypropylene SPE tubes. Simultaneous extraction of 12 samples on a 12-port Visiprep manifold requires four of these samplers. The other sampler has four tube adapters for 3mL or 6mL SPE tubes. To simultaneously extract 12 samples, three samplers are required.

The samplers consist of 1/8-inch PTFE tubing with a screw fitting at one end and a stainless steel weight at the other end. To use the sampler, feed the weighted end into a sample container until it touches the bottom. Insert the tube adapters into the conditioned SPE tubes on your Visiprep manifold. Turn on the vacuum to the Visiprep manifold and open the manifold flow control valves, and the samples will be delivered to the SPE tubes. The flow rate of sample through each tube can be independently controlled by using the flow control valves. Both the screw fittings and the PTFE tubing on the samplers are colorcoded for easy sample identification.

Also fits Preppy SPE Vacuum Manifold.

Note: The Visiprep Large Volume Sampler can only be used with polypropylene SPE tubes. You must equip alternate manifold valves with long stem flow control knobs to accommodate 12 mL, 20 mL, or 60 mL SPE tubes.

애플리케이션

Visiprep large Volume Sampler was used to extract and determine estrone in water using solid-phase extraction-enzyme-linked immunosorbent assay (SPE-ELISA). It was also used in extraction of polar pesticides from rainwater samples, during extract analysis by LC-MS-MS coupled with electrospray ionization.

법적 정보

Visiprep is a trademark of Sigma-Aldrich Co. LLC

Choose from one of the most recent versions:

시험 성적서(COA)

Lot/Batch Number

Sorry, we don't have COAs for this product available online at this time.

If you need assistance, please contact 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Development of a solid-phase extraction-enzyme-linked immunosorbent assay method for the determination of estrone in water.
Li, Zhilan, et al.
Analytica Chimica Acta, 503, 171-177 (2004)
R Bossi et al.
Journal of chromatography. A, 957(1), 27-36 (2002-07-10)
A new LC-MS-MS method for analysis of rainwater has been developed and validated for 53 pesticides, degradation products of pesticides and selected nitrophenols. The method was used to monitor the concentration of pesticides in rainwater at one location near Roskilde

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.