콘텐츠로 건너뛰기
Merck
모든 사진(1)

Key Documents

57101-U

Supelco

Visiprep 5-port Flask Vacuum Manifold

DL (Disposable Liner)

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41121800
NACRES:
NB.21

기술

solid phase extraction (SPE): suitable

응용 분야

food and beverages

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Unlike the standard Visiprep model, the Visiprep DL (disposable liner) model virtually eliminates the possibility of cross contamination when consecutive samples are extracted on the same manifold port. Threaded through each of the DL manifold ports is an inexpensive and disposable PTFE liner that runs through the solvent guide directly into the collection vessel (50 mL flask). Because reagents and samples exiting the SPE tube can only come in contact with the internal surface of the disposable liner, the risk of cross contamination when processing multiple SPE samples on the same port is virtually eliminated.
The Visiprep 5-Port Flask Vacuum Manifold enables analysts using Supelco solid phase extraction tubes to simultaneously prepare up to 5 samples. Unlike conventional vacuum manifolds, the Visiprep 5-Port Flask Manifold allows users to collect their SPE eluate directly into 50 mL round or flat bottom flasks for direct Rotovap evaporation. The manifold consists of a chemical resistant 5-port cover (DL or standard available), gasket, base, a glass basin, vacuum gauge and bleed valve, 5 flow control valves, 5 replaceable solvent guide needles, and a base plate that supports up to five 50 mL round or flat bottom flasks.

Each port on both the standard and DL Visiprep models are equipped with flow control valves.

Recommended Flasks: Aldrich single-neck flask, 50 mL, joint: ST/NS 24/40
  • Round Bottom (Cat. No. Z414484)
  • Flat Bottom (Cat. No. Z418773)

특징 및 장점

Supplied with 100 disposable liners (Part No. 57059).

법적 정보

3D Insert is a trademark of 3D Biotek, LLC
Visiprep is a trademark of Sigma-Aldrich Co. LLC

가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

죄송합니다. 지금은 이 제품에 대한 COA이(가) 온라인에서 제공되지 않습니다.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Chun-Lin Fan et al.
Journal of AOAC International, 98(1), 130-148 (2015-04-11)
A 3 month study was conducted on the ruggedness of a multiresidue method for accuracy and stability. The results indicate that in terms of Youden pair ratios of 201 pesticide aged tea samples falling approximately within 1.00-1.20 of the ratio

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.