추천 제품
product name
Ascentis® Express F5, 2.7 μm HPLC Column, 2.7 μm particle size, L × I.D. 15 cm × 2.1 mm
material
stainless steel column
Agency
suitable for USP L43
제품 라인
Ascentis®
특징
endcapped
제조업체/상표
Ascentis®
포장
1 ea of
파라미터
60 °C temp. range
600 bar max. pressure (9000 psi)
기술
HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
길이 × I.D.
15 cm × 2.1 mm
표면적
135 m2/g
불순물
<5 ppm metals
기질
Fused-Core particle platform
superficially porous particle
기질 활성군
PFP (pentafluorophenyl) phase
입자 크기
2.7 μm
공극 크기
90 Å pore size
작동 pH
2-8
응용 분야
food and beverages
분리 기술
reversed phase
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
애플리케이션
- Liquid chromatographic determination of lumacaftor in the presence of ivacaftor and identification of five novel degradation products using high-performance liquid chromatography ion trap time-of-flight mass spectrometry.: This study employs the Ascentis® Express F5, 2.7 μm HPLC Column to enhance the resolution and sensitivity in the analysis of lumacaftor and ivacaftor, critical medications for treating cystic fibrosis. The method provides significant insights into the stability and degradation pathways of these drugs, facilitating improved drug formulation and storage conditions (Ozcan et al., 2023).
- Stability-indicating LC-MS/MS and LC-DAD methods for robust determination of tasimelteon and high resolution mass spectrometric identification of a novel degradation product.: Utilizing the Ascentis® Express F5, 2.7 μm HPLC Column, this research develops advanced analytical techniques for tasimelteon, a treatment for non-24-hour sleep-wake disorder. The methods ensure accurate quantification and stability assessment, crucial for clinical efficacy and patient safety (Ozcan et al., 2020).
법적 정보
가아드 카트리지
관련 제품
애플리케이션
가장 최신 버전 중 하나를 선택하세요:
시험 성적서(COA)
문서
Novel sample prep technique coupled with the unique selectivity of the Ascentis Express F5 column enables a fast and simplified bioanalytical method for associated vitamin D metabolites.
Using HybridSPE-Phospholipid, Ascentis Express, and Other LC-MS Workflow Components
Enhanced selectivity for stereoisomers and closely related compounds with alternate selectivity from C18 phases for basic, acidic, or neutral compounds
This application shows an Ascentis Express F5 provided rapid resolution of the isobaric vitamin D metabolites. MS detection provides the necessary secondary resolution.
프로토콜
Fast and Accurate LC-MS Analysis of Vitamin D Metabolites, Using Ascentis® Express F5 HPLC Columns from Supelco®
Chromatograms
application for HPLCapplication for HPLC자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..