추천 제품
제품 라인
Carboxen®
Quality Level
형태
powder
포장
pack of 144 × 290 mg
기술
LPLC: suitable
표면적
~400 m2/g
기질
Carboxen® 564
기질 활성군
carbon
입자 크기
20-45 mesh
공극 크기
~0.13 cm3/g mesoporosity
~0.14 cm3/g macroporosity
~0.24 cm3/g microporosity
~6-9 Å pore diameter
density
~0.61 g/mL (free fall density)
분리 기술
reversed phase
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Carboxens are a highly engineered synthetic carbon adsorbent engineered from polymeric precursors. These particles will not plastically deform like resins or generate fines like activated carbon. These materials are shipped and stored dried. These derivatized resins bring value to a wide range of purification applications for removing both small and large molecule impurities. They find use in both gas and liquid phase purifications. Some examples include removal of homogenous catalysts from active pharmaceutical ingredients (API)s, high-risk impurities in biochemical purifications such as host cell proteins from mAbs, removal of toxic heavy metals, purification of chlorinated molecules, and removal of extractables and leachables. Tapered pores result in increased thermodynamic and kinetic properties for both adsorption and desorption. The Carboxens vary in the relative percentage of pore structures (micro, meso, and macro), surface area, and surface pH.
특징 및 장점
Features and Benefits:
- Spherical
- Hard (ball pan hardness >98%)
- Stable up to 400°C
- High purity
- Easy to pack
- Stable over entire pH range
- Do not create backpressure
- High osmotic shock stability
- Tapered pore sizing (from macro- to meso- to micro-)
기타 정보
For more information, please visit: specialty Carbon Adsorbents
각주
Pack of 144 ampules
법적 정보
Carboxen is a registered trademark of Merck KGaA, Darmstadt, Germany
Storage Class Code
11 - Combustible Solids
WGK
nwg
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
가장 최신 버전 중 하나를 선택하세요:
이미 열람한 고객
Applications of Solid Phase Microextraction.
Science, 64-65 (1999)
Analytical sciences : the international journal of the Japan Society for Analytical Chemistry, 24(4), 515-519 (2008-04-12)
A kind of new multi-layer adsorbent including Tenax TA/multi-walled carbon nanotubes (MWCNTs)/Carboxen 564 was developed for collecting volatile organic compounds. The adsorption and desorption efficiencies of 11 kinds of adsorbents (including Activated charcoal, Tenax TA, Carboxen 564, Chromosorb 101, Chromosorb
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 772(1), 45-51 (2002-05-23)
A new and in part automated headspace solid-phase microextraction method for quantitative determination of the highly toxic rodenticide fluoroacetic acid (FAA) in serum and other biological samples has been developed. FAA and deuterated acetic acid (internal standard) were extracted from
Chemistry & biodiversity, 8(1), 95-114 (2011-01-25)
Headspace solid-phase microextraction (HS-SPME) coupled with GC/FID and GC/MS was applied for the first time in the analysis of the volatile fraction of an Ephedra species. Notably, six Italian populations (Marche, Abruzzo, and Sardinia) of Ephedra nebrodensis subsp. nebrodensis, covering
Journal of chromatography. A, 873(1), 79-94 (2000-04-11)
The headspace solid-phase microextraction (HS-SPME) efficiencies from vegetable oil of the recently available Carboxen-poly(dimethylsiloxane) (PDMS) and divinylbenzene-Carboxen-PDMS fibres were found to be much greater than those of the PDMS fibre for a number of volatile contaminants. Using these Carboxen-based fibres
문서
Carbon Molecular sieves (CMS) are a versatile range of adsorbents that can be tailored for specific applications. Supelco® scientists have been synthesizing synthetic CMS carbons for several decades, starting from tailoring of the starting polymers/copolymers, to modifying the final properties of the subsequent CMS carbon.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.