추천 제품
생물학적 소스
human cell culture
포장
pkg of 1 ea cell microarray block (HCL003)
pkg of 2 slides (HCL001)
pkg of 5 slides (HCL002)
제조업체/상표
Histocyte
저장 온도
2-8°C
일반 설명
The HPV/p16 Analyte ControlDR has four cell line cores providing a full range of expression for Human Papilloma Virus (HPV): high, medium, low, and negative. The same cell lines also demonstrate high homogenous, high heterogenous and negative expression of p16.
HistoCyte Laboratories control slides and blocks are made from cultured human cell lines to provide the required range of expression of a specific biomarker. The cell lines are processed using proprietary methods that allow for the creation of a high density embedded cell block with cores that retain their cellular morphology. Available as pre-cut unstained slides or as cell microarray blocks for sectioning.
HistoCyte Laboratories control slides and blocks are made from cultured human cell lines to provide the required range of expression of a specific biomarker. The cell lines are processed using proprietary methods that allow for the creation of a high density embedded cell block with cores that retain their cellular morphology. Available as pre-cut unstained slides or as cell microarray blocks for sectioning.
애플리케이션
Ideal for use as a same slide control for HPV in situ hybridization (ISH) and p16 immunohistochemistry (IHC).
The HHPV/p16 Analyte ControlDR histology slides have four cell line cores providing a dynamic range of expression for HPV type 16 and 18: high, medium, low and negative. The same cell lines also demonstrate high homogenous, high heterogenous and negative expression of p16. Analyte controls are placed at one end of slide, allowing sample application on same slide for valid comparison.
The HPV/p16 Analyte ControlDR cell microarray block contains four cell line cores that are 2 mm in diameter and between 3.0-3.5 mm in length. The cell microarray block may yield over 300 sections depending on thickness.
The HHPV/p16 Analyte ControlDR histology slides have four cell line cores providing a dynamic range of expression for HPV type 16 and 18: high, medium, low and negative. The same cell lines also demonstrate high homogenous, high heterogenous and negative expression of p16. Analyte controls are placed at one end of slide, allowing sample application on same slide for valid comparison.
The HPV/p16 Analyte ControlDR cell microarray block contains four cell line cores that are 2 mm in diameter and between 3.0-3.5 mm in length. The cell microarray block may yield over 300 sections depending on thickness.
제조 메모
Cell microarray blocks are fixed in 10% neutral buffered formalin and embedded in paraffin wax. Pre-cut unstained slides are prepared from 4 μm thick sections, mounted on positively charged slides, and dried at 37 °C overnight.
기타 정보
For certificates of analysis, contact info@histocyte.com
HPV/p16 Analyte ControlDR brochure is available from HistoCyte Laboratories
HPV/p16 Analyte ControlDR brochure is available from HistoCyte Laboratories
가장 최신 버전 중 하나를 선택하세요:
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.