콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

56798

Supelco

Micro particles based on silicon dioxide

size: 1.0 μm

동의어(들):

Silicon dioxide microsphere, Micro silicon (size: 1 μm), Beads based on silicon dioxide, microsize, Silicon dioxide beads

로그인조직 및 계약 가격 보기


About This Item

MDL number:
UNSPSC 코드:
12352119
PubChem Substance ID:
NACRES:
NA.25

Grade

analytical standard

Quality Level

양식

aqueous suspension

농도

5% (solids)

입자 크기

1.0 μm

Mw/Mn

0.05

응용 분야

glass & ceramic
industrial qc
pharmaceutical

형식

neat

저장 온도

2-8°C

SMILES string

O=[Si]=O

InChI

1S/O2Si/c1-3-2

InChI key

VYPSYNLAJGMNEJ-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Silicon dioxide based microparticles (size: 1 μm) are ideal to identify particle size distribution (PSD) profile of a particle system.
The 1 μm size of the particles is characterized using CPS disc centrifuge DC 24000.

애플리케이션

Silicon dioxide beads, 1.0 μm have a wide range of uses from use as a flow agent to electrical and medical applications.
Used for calibration and regular monitoring of particle size analyzers and surface scanning instruments.
Also used to prepare glass substrates with beads for perovskite-based photovoltaic applications.

특징 및 장점

  • suitable for routine instrument calibration checks, testing and corrections
  • particle size calibrated according to NIST and SRM standards
  • available in 5 mL and 10 mL pack sizes as neat samples

Storage Class Code

10 - Combustible liquids

WGK

WGK 2

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Jason S Kim et al.
Analytical and bioanalytical chemistry, 398(6), 2373-2382 (2010-06-08)
Micron-sized particles have primarily been used in microfabricated flow cytometers for calibration purposes and proof-of-concept experiments. With increasing frequency, microparticles are serving as a platform for assays measured in these small analytical devices. Light scattering has been used to measure
Surachate Kalasin et al.
Langmuir : the ACS journal of surfaces and colloids, 26(4), 2317-2324 (2010-02-10)
This paper explores the particle-level dynamics involved in the capture of gently flowing microparticles on adhesive planar surfaces, governed by electrostatic interactions. The work focuses on conditions which produce sustained microparticle rolling, useful for the development of microfluidic devices which

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..