Key Documents

73371

Supelco

Micro particles based on polymethacrylate

analytical standard, size: 4 μm

동의어(들):

PMMA microbeads, PMMA microspheres, 2-Propenoic acid,2-methyl homopolymer, 2-methyl-2-propenoic acid homopolymer, Microparticles based on PMAA, Microparticles based on poly(methacrylic acid), Polymethacrylate

로그인조직 및 계약 가격 보기


About This Item

MDL number:
UNSPSC 코드:
41116107
NACRES:
NA.24

Grade

analytical standard

Quality Level

형태

particles
suspension

농도

10% (solids)

입자 크기

4 μm std dev <0.15 μm, coeff var <3%

형식

neat

저장 온도

2-8°C

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Polymethacrylate-based microparticles are a size standard, ideal to identify the particle size distribution (PSD) profile of test samples.
The particle size of 4 μm is measured using Coulter Multisizer.

애플리케이션

Used to qualify and check particle size equipment.
Also used to:
  • form self-assembled colloid structures for studying fluid dynamics of colloid mobility near a solid surface
  • fabricate polyelectrolyte-modified beads as an alternate option for conventional pretreatment process of electroless plating
  • validate microfluidic device for density- and size-based microparticle separation

특징 및 장점

  • suitable for routine instrument calibration checks, testing and corrections
  • traceable to Community Bureau of Reference (BCR) standards
  • available in 5 mL pack size as a neat sample

분석 메모

The exact values for particle size and standard deviation are determined for each lot and may be found on the certificate of analysis. These values are determined with an accuracy of 0.01 μm (Coulter Multisizer). Polymethacrylate based particles have a narrow size distribution and spherical shape. They are stable at temperatures of up to 100 °C Density is 1.22 g/cm3. The surface is negatively charged. Good biocompatibility and reduced nonspecific protein binding are characteristic.

Storage Class Code

12 - Non Combustible Liquids

WGK

nwg

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Preparation of PMMA-Ni core-shell composite particles by electroless plating on polyelectrolyte-modified PMMA beads
Lin KJ, et al.
Applied Surface Science, 282, 741-745 (2013)

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.