추천 제품
grade
purum p.a.
Quality Level
분석
≥99.0% (T)
형태
crystals
품질
crystallized
pH
4.0-4.5 (25 °C, 50 mg/mL in H2O)
solubility
H2O: 50 mg/mL, clear, colorless
음이온 미량물
chloride (Cl-): ≤50 mg/kg
sulfate (SO42-): ≤50 mg/kg
양이온 미량물
Ca: ≤50 mg/kg
Cd: ≤50 mg/kg
Co: ≤50 mg/kg
Cu: ≤50 mg/kg
Fe: ≤50 mg/kg
K: ≤100 mg/kg
Ni: ≤50 mg/kg
Pb: ≤50 mg/kg
Zn: ≤50 mg/kg
SMILES string
O.O.[Na+].OP(O)([O-])=O
InChI
1S/Na.H3O4P.2H2O/c;1-5(2,3)4;;/h;(H3,1,2,3,4);2*1H2/q+1;;;/p-1
InChI key
VBJGJHBYWREJQD-UHFFFAOYSA-M
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Sodium dihydrogen phosphate is an inorganic compound, which is soluble in water. Sodium dihydrogen phosphate dihydrate is used as a reagent in the development of silicate-based grouts.
애플리케이션
Sodium phosphate monobasic dihydrate has been used:
- to perform perfusion for fixed brain tissue to the validate magnetic resonance (MR) signal changes and analyze neuropathological changes in the brain
- as a component of basal salt solution to prepare biofilm minimal media (BMM) for culturing Pseudomonas aeruginosa strain PAO1
- to prepare sodium phosphate monobasic (NaH2PO4) stock solutions to make running buffer for capillary electrophoresis
Storage Class Code
13 - Non Combustible Solids
WGK
WGK 1
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves, type N95 (US)
이미 열람한 고객
Journal of chromatography. A, 1363, 331-337 (2014-07-22)
The design of experiments (DOE) is a good option for rationally limiting the number of experiments required to achieve the enantioresolution (Rs) of a chiral compound in capillary electrophoresis. In some cases, the modeled Rs after DOE analysis can be
Analytical chemistry, 87(7), 4001-4007 (2015-03-11)
RNA-cleaving DNAzymes provide a unique platform for developing biosensors. However, a majority of the work has been performed in clean buffer solutions, while the activity of some important DNAzymes in biological sample matrices is still under debate. Two RNA-cleaving DNAzymes
Biotechnology progress, 31(4), 925-936 (2015-04-11)
This article presents results of continuous multistage aqueous two-phase extraction of an immunoglobulin G1 from cell supernatant in a mixer-settler unit. An aqueous two-phase system consisting of polyethylene glycol 2000, phosphate salt, and water was applied without and with sodium
European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V, 92, 146-154 (2015-03-11)
We investigated the physicochemical properties of pH-sensitive hydroxyethyl cellulose (HEC)/hyaluronic acid (HA) complex hydrogels containing isoliquiritigenin (ILTG), and discussed potential applications as transdermal delivery systems for the treatment of skin lesions caused by pH imbalance. HA has skin compatibility and
Artificial cells, nanomedicine, and biotechnology, 42(4), 237-244 (2013-06-26)
In the present work, we designed an amperometric glucose biosensor based on nickel oxide nanoparticles (NiONPs)-modified carbon paste electrode. The biosensor was prepared by incorporation of glucose oxidase and NiONPs into a carbon paste matrix. It showed good analytical performances
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..