콘텐츠로 건너뛰기
Merck
모든 사진(3)

문서

44340

Sigma-Aldrich

AmberChrom 1X8 chloride form

chloride form, strongly basic, 200-400 mesh

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
(C10H12 · C10H10 · C8H8 · C3H9N)X
CAS Number:
MDL number:
UNSPSC 코드:
47101511
NACRES:
NA.56

Quality Level

설명

cross-linkage 8%

형태

beads

파라미터

66 °C OH- form max. temp.

수분

39-45%

손실

~40% loss on drying, 110 °C

기질

styrene-divinylbenzene (gel)

입자 크기

200-400 mesh

작동 pH

0-14

용량

1.2 meq/mL by wetted bed volume

InChI

1S/C10H12.C10H10.C8H8.C3H9N/c2*1-3-9-7-5-6-8-10(9)4-2;1-2-8-6-4-3-5-7-8;1-4(2)3/h3,5-8H,1,4H2,2H3;3-8H,1-2H2;2-7H,1H2;1-3H3

InChI key

HADXLRSCRPYPJJ-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

애플리케이션

AmberChrom 1X8 chloride form is a strongly basic (type I) anion exchange resin for fine chemical processing. AmberChrom has been used to determine trace levels of rhodium and platinum in environmental biological samples.
Strongly basic (type I) anion exchange resin for fine chemical processing; meets requirements of FDA Food Additive Regulation 21 CFR 173.25.

법적 정보

Amberchrom is a trademark of DuPont de Nemours, Inc.

Storage Class Code

10 - Combustible liquids

WGK

WGK 2

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves, type N95 (US)


Choose from one of the most recent versions:

시험 성적서(COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

P Cañada Rudner et al.
Talanta, 46(5), 1095-1105 (2008-10-31)
1,5-Bis[(2-pyridyl)-3-sulphophenyl methylene] thiocarbonohydrazide (PSTH) immobilized on an anion-exchange resin (Dowex) has been used for the on-line preconcentration of mercury from biological samples and waters prior to its determination by inductively coupled plasma atomic emission spectroscopy. The metal was eluted from
M M González García et al.
Analytical and bioanalytical chemistry, 375(8), 1229-1233 (2003-05-07)
A method to determine trace amounts of platinum in different samples based on electrothermal atomic absorption spectrometry is described. The preconcentration step is performed on a chelating resin microcolumn [1,5-bis(2-pyridyl)-3-sulfophenyl methylene thiocarbonohydrazide (PSTH) immobilized on an anion-exchange resin (Dowex 1x8-200)]
F Sánchez Rojas et al.
Talanta, 64(1), 230-236 (2008-10-31)
A method for the determination of rhodium in different samples at trace levels is presented. The investigated metal is preconcentrated on a chelating resin microcolumn (1,5-bis(2-pyridyl)-3-sulphophenyl methylene thiocarbonohydrazide (PSTH) immobilized on an anion-exchange resin (Dowex 1x8-200)) placed in the autosampler
Connor M Blair et al.
Bio-protocol, 10(7), e3581-e3581 (2021-03-05)
Cyclic nucleotide degrading phosphodiesterase (PDE) enzymes are crucial to the fine tuning of cAMP signaling responses, playing a pivotal role in regulating the temporal and spatial characteristics of discrete cAMP nanodomains and hence the activity of cAMP-effector proteins. As a

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.