콘텐츠로 건너뛰기
Merck
모든 사진(1)

Key Documents

30585

Supelco

Bis(1-butylpentyl)decane-1,10-diyl diglutarate

Selectophore

동의어(들):

5,30-Dibutyl-6,12,23,29-tetraoxatetratriacontane-7,11,24,28-tetrane, ETH 469

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
C38H70O8
CAS Number:
Molecular Weight:
654.96
MDL number:
UNSPSC 코드:
26111700
PubChem Substance ID:
NACRES:
NB.61

Grade

for ion-selective electrodes

Quality Level

제품 라인

Selectophore

분석

≥97%

형태

liquid

SMILES string

CCCCC(CCCC)OC(=O)CCCC(=O)OCCCCCCCCCCOC(=O)CCCC(=O)OC(CCCC)CCCC

InChI

1S/C38H70O8/c1-5-9-23-33(24-10-6-2)45-37(41)29-21-27-35(39)43-31-19-17-15-13-14-16-18-20-32-44-36(40)28-22-30-38(42)46-34(25-11-7-3)26-12-8-4/h33-34H,5-32H2,1-4H3

InChI key

AAEJKGTZDCFBEA-UHFFFAOYSA-N

일반 설명

Visit our Sensor Applications portal to learn more.

애플리케이션

Bis(1-butylpentyl)decane-1,10-diyl diglutarate, was used for the preparation of optode membranes, which are sodium selective and are based on neutral ionophore, primarily used for the characterization of total sodium concentration in human blood plasma. It was also used for the preparation of nitrite-selective membrane electrode, used for the potentiometric determination of NAD(P)H coenzymes.

포장

Bottomless glass bottle. Contents are inside inserted fused cone.

기타 정보

Plasticizer of high lipophilicity

법적 정보

Selectophore is a trademark of Merck KGaA, Darmstadt, Germany

Storage Class Code

10 - Combustible liquids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Ion-selective electrodes and their clinical application in the continuous ion monitoring.
W Simon et al.
Annals of the New York Academy of Sciences, 428, 279-285 (1984-01-01)
Potentiometric Determination of NAD(P)H Coenzymes Using a Nitrite-Selective Membrane Electrode and a Nitrate Reductase Enzyme and the Application to Glucose Assay in Human Serum
Katsu, T., et al.
Analytical Sciences, 15, 135-139 (1999)
Influence of the organic matrix on the properties of membrane coated ion sensor field-effect transistors
Kolytcheva, N.V., et al.
Sensors and Actuators B, Chemical, 58, 456-463 (1999)
K Seiler et al.
Clinical chemistry, 37(8), 1350-1355 (1991-08-01)
Plasticized poly(vinyl chloride) membranes that incorporate a highly lipophilic sodium-selective neutral ionophore (ETH 4120) and novel H(+)-selective chromo-ionophores, lipophilic isologs of Nile Blue, are used in the competitive binding of Na+ and H+ for a reversible, optical determination of sodium
Potentiometric Determination of NAD (P) H Coenzymes Using a Nitrite-Selective Membrane Electrode and a Nitrate Reductase Enzyme and the Application to Glucose Assay in Human Serum.
Katsu T
Analytical Sciences, 15 (2), 135-139 (1999)

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.