콘텐츠로 건너뛰기
Merck
모든 사진(1)

Key Documents

MTGR05010

Millipore

Aervent® 50 Capsule Filter

pore size 0.2 μm

동의어(들):

Aervent®-50 Filter Unit 0.2 µm hydrophobic 1/8 in. HB/HB, EPA Est. 041237-FRA-001

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
23151806
eCl@ss:
32031690
NACRES:
NB.24

material

PTFE membrane
polypropylene
polypropylene housing

Quality Level

무균

non-sterile

멸균 적합성

gamma compatible

제품 라인

Aervent®

특징

hydrophobic

제조업체/상표

Aervent®

파라미터

2.1 bar max. differential pressure at 25 °C
4.1 bar max. inlet pressure (60 psi) at 25 °C

기술

gas filtration: suitable

길이

7.1 cm (2.8 in.)

너비

2.4 in.

직경

6.2 cm (2.4 in.)

여과 면적

19.6 cm2

불순물

≤0.5 EU/mL (LAL test, Aqueous extraction)

중량 추출물

≤1.0 mg

기질

Aervent®

공극 크기

0.2 μm pore size

버블 포인트(bubble point)

≥1100 mbar (16 psig), nitrogen with 60/40% IPA/water at 23 °C

피팅

inlet/outlet hose for 4-9.5 mm I.D. latex tubing and Female Luer slip

배송 상태

ambient

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

This Aervent® hydrophobic Capsule filter contain a 50 mm Aervent PTFE membrane in a bi-directionally supported polypropylene casing. This sterilizing-grade filter, with a 0.2 μm pore size and 19.6 cm2 filtration area, is designed for critical small scale gas line and air venting applications. The hydrophobic Aervent PTFE membrane within MTGR05010 provides high flow rates and throughput, low extractables and particle shedding, and broad chemical compatibility. For traceability and easy identification, each Aervent-50 filter is hot stamped with its catalogue number and lot number. Each Aervent® Capsule Filter is integrity tested during manufacture.

애플리케이션

Typical Applications
  • Sterile venting of vessels and carboys
  • Autoclave vacuum break lines
  • Low volume sterile filtration of non-aqueous fluids
  • Small fermenter inlet and exhaust gas filtration

분석 메모

Gravimetric Extractables: in 70/30 % IPA/water

기타 정보

Directions for Use
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer Steam Sterilization & Integrity Testing Procedures guide and first page of Visual Inspection Guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

법적 정보

AERVENT is a registered trademark of Merck KGaA, Darmstadt, Germany

적합한 제품을 찾을 수 없으신가요?  

당사의 제품 선택기 도구.을(를) 시도해 보세요.


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.