추천 제품
material
brown filter
plain filter
polycarbonate membrane
무균
non-sterile
특징
hydrophilic
제조업체/상표
Isopore™
Millipore
파라미터
140 °C max. temp.
6 mL/min-cm2-psi water flow rate (maximum flow rate per 1.0 psi)
~16 mL/min-cm2 water flow rate at 10 psi (typical results)
필터 직경
13 mm
두께
25 μm
중량 추출물
<1%
색상
brown
refractive index
n/D 1.6
기질
Isopore™
공극 크기
0.22 μm pore size
5-20 % porosity
버블 포인트(bubble point)
≥5.2 bar, air with water at 23 °C
배송 상태
ambient
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Filter Code: GTBP
Filter Type: Screen filter
The Isopore membrane is a polycarbonate, track-etched screen filter recommended for all analyses in which the sample is viewed on the surface of the membrane. Isopore membrane offers distinct advantages for the analysis of airborne contaminants and other particles using optical or electron microscopy. The Isopore membrane is composed of polycarbonate film, which has a smooth, glass-like surface for clearer sample observation. The unique manufacturing process of the membrane ensures a precise pore diameter and a consistent pore size for accurate separation of samples by size. Matched-weight filters are not usually required because of low, constant tar and ash weights.
Features & Benefits:
•Membrane structure retains particles on the surface, simplifying counting and analysis
•Isopore membranes do not stain, resulting in low background interference
•Non-hygroscopic, allowing for rapid drying and reduced sample analysis time
•Translucent material does not require clearing for transmitted light microscopy; also available in brown variety
Applications:
Air Monitoring, Epifluorescent Microscopy, Chemotaxis Assays
Features & Benefits:
•Membrane structure retains particles on the surface, simplifying counting and analysis
•Isopore membranes do not stain, resulting in low background interference
•Non-hygroscopic, allowing for rapid drying and reduced sample analysis time
•Translucent material does not require clearing for transmitted light microscopy; also available in brown variety
Applications:
Air Monitoring, Epifluorescent Microscopy, Chemotaxis Assays
애플리케이션
- Epifluorescent microscopy
- Particle monitoring
- Air monitoring
- Microplastics analysis
- Microplastics analysis grade water
주의사항
Possible reduction in flow rates may occur after autoclaving.
법적 정보
ISOPORE is a trademark of Merck KGaA, Darmstadt, Germany
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.