콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

CC105

Sigma-Aldrich

Human Integrin α5β1 Protein, Triton X-100 Formulation

동의어(들):

VLA-5

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
12352202
eCl@ss:
32160405
NACRES:
NA.77

생물학적 소스

human

Quality Level

양식

liquid

제조업체/상표

Chemicon®

불순물

CONTAMINANT(S)
none detected

NCBI 수납 번호

UniProt 수납 번호

유전자 정보

human ... ITGA5(3678)

일반 설명

Integrin a5/b1 purified from smooth muscle and placental tissue under nondenaturing conditions by affinity chromatography on fibronectin-Sepharose (Belkin, 1990).



Two main protein bands corresponding to a5 (145 kD) and beta1 (120 kD) subunits are seen in silver stained 7.5%

polyacrylamide gels under nonreduced conditions. Minor protein band at the 210 kD corresponding to beta1 subunit disulfide dimmer, which is formed during electrophoresis and disappears after reduction.
Product Source: Human smooth muscle and placental tissue.

애플리케이션

Electrophoresis and Immunoblotting control. Due to the existance of reduction sensitive sites within the integrin subunits, it is recommended that gels be run under non-reducing conditions for best results. Under non-reducing conditions, the alpha5 subunit will migrate at 155 kDa while the beta1 subunit will migrate at 110 kDa.

Function: Liposomes containing Integrin alpha5/beta1 adhere to surfaces coated with fibronectin in an RGD-dependent fashion.

물리적 형태

Purified protein in 20 mM Tris-HCl, pH 7.5, 150 mM NaCl, 2 mM MgCl2 containing 0.2% Triton X-100. No preservatives. Source material for the enclosed purified human proteins, Integrin alpha5beta1, has been tested for antibodies to HIV, HCV, and HbsAg and found to be negative by an approved test.

저장 및 안정성

Maintain at -70°C in undiluted aliquots. Avoid repeated freeze/thaw cycles.

분석 메모

Nonreduced SDS-PAGE of 15 mg on 5-15% polyacrylamide slab gel and staining with Coomassie shows only two main bands at 110 kDa (beta1 subunit) and 155 kDa (alpha5 subunit).A weak band at 205 kDa is due to dimerization of the b1 subunit (Belkin et al., 1996)

법적 정보

CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany

면책조항

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Storage Class Code

12 - Non Combustible Liquids

WGK

WGK 2

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.