추천 제품
product name
SeQuant™ ZIC-HILIC™ 3.5µm,200Å 150 x 2.1 mm, PEEK-lined stainless steel column, suitable for HPLC
material
PEEK-lined stainless steel column
Quality Level
Agency
suitable for USP L114
제품 라인
SeQuant™
특징
endcapped: no
파라미터
550 bar pressure
70 °C max. temp.
기술
HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
mass spectrometry (MS): suitable (High)
컬럼 길이 × I.D.
15 cm × 2.1 mm
기질
fully porous particle
기질 활성군
ZIC-HILIC bonding phase
입자 크기
3.5 μm
공극 크기
200 Å pore size
작동 pH
2-7.5
분리 기술
hydrophilic interaction (HILIC)
저장 온도
no temp limit
일반 설명
SeQuant™ ZIC®-HILIC Columns are designed to retain and separate all types of polar and hydrophilic compounds and for robust chromatography with high selectivity and reproducibility. The silica-based ZIC®-HILIC sorbent has a bonded stationary phase consisting of a highly polar, permanent zwitterion. Separation selectivity is favored by the 1:1 zwitterion charge balance, which makes the ZIC®-HILIC Column overall neutral, with weak, but important, ionic interactions. Tuning of the selectivity on the ZIC®-HILIC Column during method development is facilitated by the pH-inpendent permanent zwitterion, ensuring that only the analytes (and not the column) are affected during eluent optimization.The Pore size of 200 Å makes this column perfectly suitable for the separation of larger polar molecules under HILIC conditions.The column dimension of 150 mm length x 2.1 mm ID is the optimal choice for the separation of polar compounds using a UHPLC or optimized HPLC Instrument providing low dwell volumes.Thanks to their favorable retention and robust performance, SeQuant™ HILIC columns have become extremely popular in numerous laboratories around the world. For example, US FDA (United States Food and Drug Administration) has recommended SeQuant™ ZIC®-HILIC for analysis of melamine and related substances. SeQuant™ HILIC columns excel in stability and low bleed. These features make them particularly suitable for LC-MS applications where high background can lead to signal suppression and interference with quantitative measurements while also increasing instrument wear. Their high stability makes these high-performance HILIC columns also attractive for traditional HPLC applications.Learn more about the Supelco HPLC Column portfolio and Method development:Brochure: HPLC and UHPLC Column Selection Guide Brochure: A Practical Guide to HPLC - Method Development Guide
애플리케이션
- Click postsynthesis of microporous organic network@silica composites: Demonstrates the application of SeQuant ZIC-HILI columns in mixed-mode chromatography, particularly in the synthesis of composites that facilitate both reversed-phase and hydrophilic interaction chromatography. This approach is crucial for advanced pharmaceutical compound analysis and biomolecule separation technology (Sun HF et al., 2023).
- Evaluation of Hold-Up Volume Determination Methods and Markers in Hydrophilic Interaction Liquid Chromatography: Focuses on refining the precision in volume determinations using ZIC-HILIC columns, enhancing method development for pharmaceuticals and providing a basis for high-resolution mass spectrometry applications (Redon L et al., 2023).
- Determination of the polyphenolic content of berry juices: Utilizes SeQuant ZIC-HILIC technology for comprehensive two-dimensional liquid chromatography, essential for complex sample analysis in food safety and quality assessments (Arena K et al., 2023).
- Simple and sensitive determination of sulfites in Chinese herbal teas: Highlights the robustness of SeQuant ZIC-HILIC in ultra-high-performance liquid chromatography tandem mass spectrometry, ensuring the safety and compliance of herbal products with stringent health standards (Yang L et al., 2022).
분석 메모
Theoretical Plates (N/m) (Cytosine): ≥ 90000
Symmetry (Cytosine): 0.95 - 1.40
Symmetry (Cytosine): 0.95 - 1.40
법적 정보
SeQuant is a trademark of Merck KGaA, Darmstadt, Germany
ZIC is a registered trademark of Merck KGaA, Darmstadt, Germany
ZIC-HILIC is a trademark of Merck KGaA, Darmstadt, Germany
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.