콘텐츠로 건너뛰기
Merck
모든 사진(1)

Key Documents

1.50435

Supelco

SeQuant ZIC®-HILIC 200Å (5 µm) HPLC Columns

L × I.D. 20 mm x 2.1 mm Guard Column

동의어(들):

Hydrophilic Interaction Liquid Chromatography Guard Column

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41115709

product name

SeQuant ZIC-HILIC Guard 20 x 2.1 mm, PEEK-lined stainless steel column, suitable for HPLC

material

PEEK-lined stainless steel column

Quality Level

Agency

suitable for USP L114

제품 라인

SeQuant

특징

endcapped: no

파라미터

550 bar pressure
70 °C max. temp.

기술

HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
mass spectrometry (MS): suitable (High)

컬럼 길이 × I.D.

2 cm × 2.1 mm

기질

fully porous particle

기질 활성군

ZIC-HILIC bonding phase

입자 크기

5 μm

공극 크기

200 Å pore size

작동 pH

1.5-7.5

분리 기술

hydrophilic interaction (HILIC)

저장 온도

no temp limit

일반 설명

The SeQuant ZIC®-HILIC Guard column protects your analytical separation column from contamination.
SeQuant ZIC®-HILIC Columns are designed to retain and separate all types of polar and hydrophilic compounds and for robust chromatography with high selectivity and reproducibility.
The silica-based ZIC®-HILIC sorbent has a bonded stationary phase consisting of a highly polar, permanent zwitterion. Separation selectivity is favored by the 1:1 zwitterion charge balance, which makes the ZIC®-HILIC Column overall neutral, with weak, but important, ionic interactions. Tuning of the selectivity on the ZIC®-HILIC Column during method development is facilitated by the pH-inpendent permanent zwitterion, ensuring that only the analytes (and not the column) are affected during eluent optimization.
Thanks to their favorable retention and robust performance, SeQuant HILIC columns have become extremely popular in numerous laboratories around the world. For example, US FDA (United States Food and Drug Administration) has recommended SeQuant ZIC®-HILIC for analysis of melamine and related substances. SeQuant HILIC columns excel in stability and low bleed. These features make them particularly suitable for LC-MS applications where high background can lead to signal suppression and interference with quantitative measurements while also increasing instrument wear. Their high stability makes these high-performance HILIC columns also attractive for traditional HPLC applications.
Learn more about the Supelco HPLC Column portfolio and Method development:
Brochure: HPLC and UHPLC Column Selection Guide
Brochure: A Practical Guide to HPLC - Method Development Guide

애플리케이션


  • Development and validation of LC-MS/MS methods to measure tobramycin and lincomycin: Demonstrates the application of SeQuant ZIC-HILIC Guard columns in a pharmacokinetic research study, focusing on the high-precision measurement of pharmaceutical compounds in biological matrices. This method is essential for ensuring accurate dosage and monitoring therapeutic levels, crucial for clinical trials and medical research (Pandey S et al., 2020).

분석 메모

Extent of testing: conforms

법적 정보

SeQuant is a trademark of Merck KGaA, Darmstadt, Germany
ZIC is a registered trademark of Merck KGaA, Darmstadt, Germany
ZIC-HILIC is a trademark of Merck KGaA, Darmstadt, Germany

시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.