콘텐츠로 건너뛰기
Merck
모든 사진(4)

주요 문서

1.17421

Millipore

Safe Lid for MAS-100 NT®

for use with MAS-100 NT®, sterile; irradiated (Alternative to the standard autoclavable perforated lid), ready-to-use, box of 30 units

동의어(들):

Ready-to use Perforated Lid, Sterile Perforated Lid

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41103403
NACRES:
NA.74

material

acrylonitrile-butadiene-styrene (ABS) lid

Quality Level

무균

sterile; irradiated (Alternative to the standard autoclavable perforated lid)

특징

disposable
ready-to-use

포장

box of 30 units

제조업체/상표

MAS-100 NT®

응용 분야

pharmaceutical

호환성

for use with MAS-100 NT®

일반 설명

Safe Lid for MAS-100 NT® is a disposable alternative to the autoclavable standard perforated lid made from aluminum (ref. 1.09195). It is made of 100% recyclable acrylonitrile butadiene styrene (ABS) and comes in 30 individually double-packed and sterilized pieces per package.

Safe Lid has the same sieve configuration as the standard perforated lid with 300 holes of 0.6 mm diameter. This ensures an identical impact velocity of 19.6 m/s and a nominal d50 of 1.1 μm. The simplified validation of the recovery rates according to EN 17141 resulted in comparable values for both perforated lids.

애플리케이션

The application of the disposable lid on the MAS-100 NT® air sampler is identical to that of the standard perforated lid. You may follow the user instructions of MAS-100 NT®. The only difference is the lack of a twist fastener, which simplifies handling even more.

특징 및 장점

  • Collection efficiency of ISO 14698 validated MAS-100 NT® is comparable for standard perforated lids and Safe Lid (verified by simplified validation acc. EN 17141).
  • Reproducible results thanks to 100% visual, camera-based control of the holes.
  • Flow rate with MAS-100 NT® is 100 SLPM ± 5% .
  • By using the Safe Lid, at least 10% more samples can be taken per battery charge.
  • Enable tracking for digital data analysis and trending based on individual GS1 barcode.
  • Thanks to the ready-to-use and sterile format, no daily autoclaving process is required.
  • The non-twisting closure allows quick exchange of lids and supports robotic handling.
  • Individual barcodes enable tracking using digital workflows.
  • The prevention of cross-contamination during transfer into cleanrooms is ensured by the individual double packaging.
  • Sterility prevents false positives.
  • Single use followed by disposal minimizes the risk of exposure to potentially toxic airborne substances.

법적 정보

MAS-100 NT is a registered trademark of MBV AG

시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.