product name
LiChrospher® 100 RP-18 (5 µm),
material
stainless steel column
Agency
suitable for USP L1
제품 라인
LiChrospher®
특징
endcapped: no
포장
1 ea of
라벨링 범위
21% Carbon loading
파라미터
60 °C max. temp.
기술
HPLC: suitable
mass spectrometry (MS): suitable (Low - Medium)
표면적
350 m2/g
기질
fully porous particle
기질 활성군
C18 bonding phase
입자 크기
5 μm
공극 크기
100 Å pore size
operating pH range
2-7.5
벌크 밀도
200‑400 kg/m3
분리 기술
reversed phase
저장 온도
no temp limit
일반 설명
LiChrospher® RP-18 is a reliable and versatile traditionally produced spherical silica gel carrier with C-18 reversed phase properties. It is well suited for the separation of neutral, acidic and weak basic compounds.
애플리케이션
- Fast Determination of a Novel Iron Chelate Prototype Used as a Fertilizer by Liquid Chromatography Coupled to a Diode Array Detector.: This study explores the use of LiChrospher® 100 RP-18 (5 µm) for the rapid analysis of a new iron chelate fertilizer, showcasing its effectiveness in agricultural applications (Valverde et al., 2021).
- Application of Chemometric Approach for Development and Validation of High-Performance Liquid Chromatography Method for Estimation of Ropinirole Hydrochloride.: The research utilizes LiChrospher® 100 RP-18 (5 µm) for the quantification of ropinirole in pharmaceutical formulations, highlighting its precision and robustness (Fatima et al., 2019).
- Quantification of Alprenolol and Propranolol in Human Plasma Using a Two-Dimensional Liquid Chromatography (2D-LC).: This paper demonstrates the application of LiChrospher® 100 RP-18 (5 µm) in clinical settings for the analysis of beta-blockers in plasma, indicating its utility in pharmacokinetics (Gonçalves et al., 2017).
- Ultrasound-Assisted Surfactant-Enhanced Emulsification Micro-Extraction Followed by HPLC for Determination of Preservatives in Water, Beverages, and Personal Care Products.: The study highlights the use of LiChrospher® 100 RP-18 (5 µm) for environmental and quality control analyses, demonstrating its versatility in various matrices (Jan-E et al., 2017).
- Development and Validation of Stability-Indicating HPLC Method for Determination of Cefpirome Sulfate.: This research focuses on the stability testing of cefpirome using LiChrospher® 100 RP-18 (5 µm), emphasizing its reliability for pharmaceutical quality control (Zalewski et al., 2014).
분석 메모
Application test: passes test
Pressure: ≤ 35 bar
Theoretical Plates (N/m) (Toluene): ≥ 60000
stability testing (performance): passes test
separation factor (Acetophenone/Phenol, selectivity test): 2.05 - 2.25
separation factor (Acetophenone/Cinnamic acid, selectivity test): 1.24 - 1.37
capacity factor (Toluene): 13.0 - 18.0
Pressure: ≤ 35 bar
Theoretical Plates (N/m) (Toluene): ≥ 60000
stability testing (performance): passes test
separation factor (Acetophenone/Phenol, selectivity test): 2.05 - 2.25
separation factor (Acetophenone/Cinnamic acid, selectivity test): 1.24 - 1.37
capacity factor (Toluene): 13.0 - 18.0
법적 정보
LiChrospher is a registered trademark of Merck KGaA, Darmstadt, Germany
Storage Class Code
11 - Combustible Solids
WGK
nwg
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.