콘텐츠로 건너뛰기
Merck
모든 사진(1)

Key Documents

1.16129

Supelco

LiChrospher® 100 RP-8 (5 µm) HPLC Columns

HPLC sorbent

동의어(들):

TM=["LiChrospher"] C8 sorbent for HPLC

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41115709
NACRES:
SB.52

product name

LiChrospher® 100 RP-8 (5 µm),

material

stainless steel column

Agency

suitable for USP L7

제품 라인

LiChrospher®

특징

endcapped: no

라벨링 범위

12.5% Carbon loading

파라미터

60 °C max. temp.

기술

HPLC: suitable
mass spectrometry (MS): suitable (Low - Medium)

표면적

350 m2/g

기질

fully porous particle

기질 활성군

C8 bonding phase

입자 크기

5 μm

공극 크기

100 Å pore size

operating pH range

2-7.5

벌크 밀도

200‑400 kg/m3

분리 기술

reversed phase

저장 온도

no temp limit

일반 설명

LiChrospher® RP-8 is a reliable and versatile traditionally produced spherical silica gel carrier with C-8 reversed phase properties. It is well suited for the separation of neutral, acidic and weak basic compounds.

애플리케이션


  • Development and validation of a HPLC-UV method for the determination in didanosine tablets.: This study presents a validated HPLC-UV method optimized using LiChrospher® 100 RP-8 (5 µm) for analyzing didanosine in tablet formulations, offering a reliable tool for quality control in pharmaceutical environments (de Oliveira et al., 2005).

  • Determination of steroid hormones in oral contraceptives by high-performance liquid chromatography.: Utilizes LiChrospher® 100 RP-8 (5 µm) to effectively separate and quantify steroid hormones in oral contraceptive pills, demonstrating the column′s applicability in complex pharmaceutical analyses (Inês et al., 2002).

  • Determination of fluoroquinolone residues in animal tissues by liquid chromatography.: Explores the use of LiChrospher® 100 RP-8 (5 µm) for the sensitive detection of fluoroquinolone residues in animal tissues, highlighting its potential for food safety and veterinary medicine applications (Posyniak et al., 1999).

  • Rapid and simple determination of oxytetracycline in chicken products.: Demonstrates the column′s efficiency in rapidly quantifying oxytetracycline residues in chicken, ensuring compliance with food safety standards (Furusawa, 1999).

  • Crocheted ETFE-reactor for on-line post-column photoderivatization of diclofenac in high-performance liquid chromatography.: Describes an innovative application involving LiChrospher® 100 RP-8 (5 µm) in a post-column reactor setup to enhance the detection sensitivity of diclofenac, underlining the column′s versatility in advanced analytical techniques (Kuhlmann et al., 1997).


분석 메모

Application test: passes test
Pressure: ≤ 45 bar
Theoretical Plates (N/m) (Toluene): ≥ 60000
Capacity factor (Toluene): ≥ 0.7
stability testing (performance): passes test
separation factor (PTH-Lysine/PHB-Propyl-Ester, selectivity test): 1.20 - 1.55
separation factor (Naphthalene/Digitoxigenin, selectivity test): 3.5 - 4.7
separation factor (PTH-Lysine/Digitoxigenin, selsctivity test): 1.70 - 2.25
Particle Size (d10): 4.8 - 5.5 µm
Particle Size (d50): 6.5 - 7.5 µm
Particle Size (d90): 9.0 - 10.5 µm

법적 정보

LiChrospher is a registered trademark of Merck KGaA, Darmstadt, Germany

Storage Class Code

11 - Combustible Solids

WGK

nwg

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.