추천 제품
product name
LiChrospher® 100 RP-8 (5 µm),
material
stainless steel column
Agency
suitable for USP L7
제품 라인
LiChrospher®
특징
endcapped: no
라벨링 범위
12.5% Carbon loading
파라미터
60 °C max. temp.
기술
HPLC: suitable
mass spectrometry (MS): suitable (Low - Medium)
표면적
350 m2/g
기질
fully porous particle
기질 활성군
C8 bonding phase
입자 크기
5 μm
공극 크기
100 Å pore size
operating pH range
2-7.5
벌크 밀도
200‑400 kg/m3
분리 기술
reversed phase
저장 온도
no temp limit
일반 설명
LiChrospher® RP-8 is a reliable and versatile traditionally produced spherical silica gel carrier with C-8 reversed phase properties. It is well suited for the separation of neutral, acidic and weak basic compounds.
애플리케이션
- Development and validation of a HPLC-UV method for the determination in didanosine tablets.: This study presents a validated HPLC-UV method optimized using LiChrospher® 100 RP-8 (5 µm) for analyzing didanosine in tablet formulations, offering a reliable tool for quality control in pharmaceutical environments (de Oliveira et al., 2005).
- Determination of steroid hormones in oral contraceptives by high-performance liquid chromatography.: Utilizes LiChrospher® 100 RP-8 (5 µm) to effectively separate and quantify steroid hormones in oral contraceptive pills, demonstrating the column′s applicability in complex pharmaceutical analyses (Inês et al., 2002).
- Determination of fluoroquinolone residues in animal tissues by liquid chromatography.: Explores the use of LiChrospher® 100 RP-8 (5 µm) for the sensitive detection of fluoroquinolone residues in animal tissues, highlighting its potential for food safety and veterinary medicine applications (Posyniak et al., 1999).
- Rapid and simple determination of oxytetracycline in chicken products.: Demonstrates the column′s efficiency in rapidly quantifying oxytetracycline residues in chicken, ensuring compliance with food safety standards (Furusawa, 1999).
- Crocheted ETFE-reactor for on-line post-column photoderivatization of diclofenac in high-performance liquid chromatography.: Describes an innovative application involving LiChrospher® 100 RP-8 (5 µm) in a post-column reactor setup to enhance the detection sensitivity of diclofenac, underlining the column′s versatility in advanced analytical techniques (Kuhlmann et al., 1997).
분석 메모
Application test: passes test
Pressure: ≤ 45 bar
Theoretical Plates (N/m) (Toluene): ≥ 60000
Capacity factor (Toluene): ≥ 0.7
stability testing (performance): passes test
separation factor (PTH-Lysine/PHB-Propyl-Ester, selectivity test): 1.20 - 1.55
separation factor (Naphthalene/Digitoxigenin, selectivity test): 3.5 - 4.7
separation factor (PTH-Lysine/Digitoxigenin, selsctivity test): 1.70 - 2.25
Particle Size (d10): 4.8 - 5.5 µm
Particle Size (d50): 6.5 - 7.5 µm
Particle Size (d90): 9.0 - 10.5 µm
Pressure: ≤ 45 bar
Theoretical Plates (N/m) (Toluene): ≥ 60000
Capacity factor (Toluene): ≥ 0.7
stability testing (performance): passes test
separation factor (PTH-Lysine/PHB-Propyl-Ester, selectivity test): 1.20 - 1.55
separation factor (Naphthalene/Digitoxigenin, selectivity test): 3.5 - 4.7
separation factor (PTH-Lysine/Digitoxigenin, selsctivity test): 1.70 - 2.25
Particle Size (d10): 4.8 - 5.5 µm
Particle Size (d50): 6.5 - 7.5 µm
Particle Size (d90): 9.0 - 10.5 µm
법적 정보
LiChrospher is a registered trademark of Merck KGaA, Darmstadt, Germany
Storage Class Code
11 - Combustible Solids
WGK
nwg
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.