콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

450596

Sigma-Aldrich

Poly(ethylene glycol) bis(2-ethylhexanoate)

average Mn ~650

동의어(들):

PEG bis(2-ethylhexanoate)

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
CH3(CH2)3CH(C2H5)CO(OCH2CH2)nO2CCH(C2H5)(CH2)3CH3
CAS Number:
MDL number:
UNSPSC 코드:
12162002
PubChem Substance ID:
NACRES:
NA.23

분자량

average Mn ~650

Quality Level

refractive index

n20/D 1.453 (lit.)

점도

50 cP(25 °C)(lit.)

mp

−48 °C (lit.)

solubility

H2O: insoluble
hexane, toluene, ethanol, and acetone: soluble

density

1.02 g/mL at 25 °C (lit.)

SMILES string

OCCO.CCCCC(CC)C(O)=O

InChI

1S/C18H34O4/c1-5-9-11-15(7-3)17(19)21-13-14-22-18(20)16(8-4)12-10-6-2/h15-16H,5-14H2,1-4H3

InChI key

XCQFTFZCTGZCNP-UHFFFAOYSA-N

일반 설명

Poly(ethylene glycol) bis(2-ethylhexanoate) (PEG-EH) is an ethylene acrylic elastomer that can be used as a low volatile plasticizer.

애플리케이션

PEG-EH can form a blend with polyvinylidene fluoride (PVDF) which can be used in the preparation of electrolytes for lithium batteries. It is also used as an additive for the development of ionization methods for mass spectroscopy.

특징 및 장점

Low volatility and good heat resistance. Compatible with a variety of polymers including polyesters and polyamides.

Storage Class Code

10 - Combustible liquids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Novel microporous poly (vinylidene fluoride) blend electrolytes for lithium-ion batteries
Wang H, et al.
Journal of the Electrochemical Society, 147(8), 2853-2861 (2000)
Jonathan P Williams et al.
Rapid communications in mass spectrometry : RCM, 21(11), 1693-1704 (2007-05-03)
A rapid method for the characterisation of polyglycol esters and ethers is described which uses accurate mass desorption electrospray ionisation (DESI) quadrupole time-of-flight mass spectrometry (Q-ToFMS). The results are combined with newly developed software which aids the interpretation of product
Klaus E Andersen et al.
Contact dermatitis, 70(2), 112-116 (2013-10-25)
Allergic reactions to spectacle frames are not unusual. A patient had a reproducible strong allergic patch test reaction to scrapings from the plastic material, and negative patch test results with available spectacle frame chemicals. To identify the culprit allergen in
A novel all-solid electrolyte based on a co-polymer of poly-(methoxy/hexadecal-poly (ethylene glycol) methacrylate) for lithium-ion cell
Zuo X, et al.
Journal of Materials Chemistry, 22(41), 22265-22271 (2012)
Research and development topics in Analytical Chemistry. Investigation of a cation exchange separation method for the determination of transition metal ions in anaerobic sealants
O'Dea P, et al.
Anal. Proc., 28(3), 82-84 (1991)

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.