콘텐츠로 건너뛰기
Merck
모든 사진(2)

주요 문서

429252

Sigma-Aldrich

Poly(ethylene terephthalate)

granular

동의어(들):

PET

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
(C10H8O4)n
CAS Number:
MDL number:
UNSPSC 코드:
12162002
PubChem Substance ID:
NACRES:
NA.23

마모 저항도

30 mg (Taber, CS-17 wheel, 1kg, 50% RH, 1,000 cycles)

Quality Level

설명

30% glass fiber to enhance hardness and strength

양식

granular

경도

120 (Rockwell R, ASTM D 785)

mp

250-255 °C

density

1.68 g/mL at 25 °C

SMILES string

OCCO.OC(=O)c1ccc(cc1)C(O)=O

InChI

1S/C8H6O4.C2H6O2/c9-7(10)5-1-2-6(4-3-5)8(11)12;3-1-2-4/h1-4H,(H,9,10)(H,11,12);3-4H,1-2H2

InChI key

FYIBGDKNYYMMAG-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

애플리케이션

Used in electrical parts including relay bases and lamp sockets, pump housings, gears, sprockets, chair arms, casters and furniture components.

특징 및 장점

Balance of strength, stiffness and toughness, excellent electrical properties, surface appearance and chemical resistance.

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves, type N95 (US)


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Leonardo Pantoja Munoz et al.
Environmental science and pollution research international, 25(20), 20268-20279 (2018-06-28)
The introduction to the market of wet wipes, advertised and labelled as "flushable", has been the subject of controversy due to their perceived potential to block sewer systems as observed with other non-woven cloths such as traditional non-flushable wipes. Non-woven
John A Martin et al.
Hand clinics, 29(1), 143-148 (2012-11-22)
We have searched for a synthetic substitute for the carpal ligaments, which would be widely available and easy to use. Four loops of 2-0 polyester fiber suture (Mersilene) were found to exceed the ultimate tensile strength of the scapholunate interosseous
Marwan A Wehbé et al.
Hand clinics, 29(1), 149-154 (2012-11-22)
Carpal ligaments are commonly injured and may lead to pain and disability. These ligaments are very difficult to repair, and the results are unpredictable; as a result, treatment options abound. A novel approach is presented here using a polyester suture
Marwan A Wehbé et al.
Hand clinics, 29(1), 27-35 (2012-11-22)
The reason there are numerous techniques for thumb carpometacarpal arthroplasty is that none of them are perfect. Sometimes the simplest procedures work best. This article presents a simple alternative, using a readily available suture to stabilize the thumb after resection
Ziaeddin Tabatabaee et al.
Ophthalmic plastic and reconstructive surgery, 27(2), 114-118 (2010-09-11)
To compare the exposure rate of wrapped hydroxyapatite versus unwrapped porous polyethylene orbital implants in enucleated patients. Medical records of the patients who underwent primary placement of hydroxyapatite (Bio-Eye) or porous polyethylene (Medpor) orbital implants after enucleation between 2002 and

Global Trade Item Number

SKUGTIN
429252-1KG
429252-5KG
429252-250G4061832105482

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..