추천 제품
vapor pressure
15 mmHg ( 32 °C)
Quality Level
형태
beads or pellets
용융 지수
20-35 g/10 min (230°C/3.8kg)
분자량
average Mn ~71,000
average Mw ~180,000 by GPC
충격 강도
2-4 ft-lb/in. (Izod, ASTM D 256, notched)
유전 상수
8.0-9.5, 100 Hz (ASTM D 150)
경도
76-80 (Shore D, ASTM D 2240)
refractive index
n20/D 1.42
ASTM D 3835
6,000-7,500 poise(230 °C) (100 sec-1)(lit.)
전이 온도
brittleness temperature -62 °C (ASTM D 746)
Tm 155-165 °C
solubility
some polar solvents such as organic esters and amines: soluble
density
1.78 g/mL at 25 °C
SMILES string
FC(F)=C
InChI
1S/C2H2F2/c1-2(3)4/h1H2
InChI key
BQCIDUSAKPWEOX-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
Coatings, film, filter cloth, instrument linings, filtration membranes, pump parts and linings and valves.
특징 및 장점
Crystallizes in at least 3 forms, depending on crystallization conditions. High mechanical strength,abrasion resistance and dielectric strength. Resists most chemicals, UV radiation, weathering and fungi.
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves, type N95 (US)
이미 열람한 고객
Journal of biomedical materials research. Part A, 101(2), 537-546 (2012-08-29)
For tissue engineering and regenerative medicine, stem cells should be effectively cultured in vitro. New thermoresponsive nanocomposite gels (MD-NC gels), consisting of inorganic clay (hectorite) and copolymers composed of hydrophobic 2-methoxyethyl acrylate (MEA) and hydrophilic N,N-dimethylacrylamide (DMAA) units, could be
The Journal of the Acoustical Society of America, 132(6), 3826-3831 (2012-12-13)
A tone analyzer is demonstrated using a distributed resonator architecture on a tensioned piezoelectric polyvinyledene diuoride (PVDF) sheet. This sheet is used as both the resonator and detection element. Two architectures are demonstrated; one uses distributed, directly addressed elements as
Klinichna khirurhiia, (7)(7), 37-41 (2012-10-05)
The results of experimental and clinical studies for the comparative evaluation of implants used in herniology of polytetrafluoroethylene (PTFE) and polyvinylidene fluoride (PVDF) are presented. Experimental investigations conducted on 200 mice, which in the anterior abdominal wall mesh prosthesis implanted.
Water science and technology : a journal of the International Association on Water Pollution Research, 67(3), 477-484 (2012-12-04)
In the present study, nano-sized TiO(2)/Al(2)O(3) modified polyvinylidene fluoride (PVDF) membranes (MM) were fabricated and then utilized for oil/water emulsion separation. The results showed that, compared with PVDF membrane (OM), the contact angle of MM decreased and hydrophilicity increased. The
Water research, 47(2), 911-921 (2012-12-12)
Organic fouling remains a significant challenge in the application of ultrafiltration (UF) pretreatment systems in the desalination industry. In this study, the fouling potential of organic materials in seawater was investigated using model seawater solution containing humic acid and alginate.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.