콘텐츠로 건너뛰기
Merck
모든 사진(2)

주요 문서

374350

Sigma-Aldrich

Tridodecylmethylammonium iodide

97%

동의어(들):

Methyltridodecylammonium iodide

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
[CH3(CH2)11]3N(I)CH3
CAS Number:
Molecular Weight:
663.93
Beilstein:
4260774
MDL number:
UNSPSC 코드:
12352116
PubChem Substance ID:
NACRES:
NA.22

Quality Level

분석

97%

mp

106-107 °C (lit.)

SMILES string

[I-].CCCCCCCCCCCC[N+](C)(CCCCCCCCCCCC)CCCCCCCCCCCC

InChI

1S/C37H78N.HI/c1-5-8-11-14-17-20-23-26-29-32-35-38(4,36-33-30-27-24-21-18-15-12-9-6-2)37-34-31-28-25-22-19-16-13-10-7-3;/h5-37H2,1-4H3;1H/q+1;/p-1

InChI key

JRLISGAUAJZAGL-UHFFFAOYSA-M

유사한 제품을 찾으십니까? 방문 제품 비교 안내

애플리케이션

Tridodecylmethylammonium iodide (3C12MAI) can be used:
  • As a triple-chained cationic surfactant.
  • to prepapre glucose oxidase enzyme immobilized iodide electrode for the detection of glucose concentration.
  • As a cationic phase-transfer catalyst in the oxidation of hydrocarbons by O2.

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves, type N95 (US)


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

The role of onium salts in the oxidation of hydrocarbons by O 2 catalysed by cationic phase-transfer reagents
Csanyi L, et al.
Physical Chemistry Chemical Physics, 2(17), 3801-3805 (2000)
Preparation and application of a new glucose sensor based on iodide ion selective electrode
K Sukru, et al.
Talanta, 65(1), 87-91 (2005)
A B Packard et al.
Nuclear medicine and biology, 22(7), 887-891 (1995-10-01)
Iridium-191m is an attractive radionuclide for first-pass radionuclide angiography, but development of an 191Os/191mIr generator with high 191mIr yield has proven difficult. The use of trans-dioxobisoxalatoosmate(VI) as a parent species results in a higher initial yield (20 to 25%/mL), but
Y B Kim et al.
Journal of Korean medical science, 9(5), 357-361 (1994-10-01)
Expanded polytetrafluoroethylene(ePTFE) grafts 4mm long and 1mm in diameter were implanted into the iliac artery of 100-150g male rats using standard microvascular technique. Prior to clamp removal, the cremaster muscle was isolated as an island flap based on the iliac
A J Freeman et al.
Journal of pharmacological methods, 23(1), 7-11 (1990-03-01)
The patency of chronically implanted intravascular cannulae is usually limited by thrombus formation at the cannula tip. In the present experiments, methods of improving the antithrombotic properties of the cannulae have been examined using a number of different heparin-bonding treatments.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.