Sigma-Aldrich

Poly(ethylene oxide)

average MV 900,000 (nominal), powder, hydroxyl, BHT as inhibitor

동의어(들):

Polyethylene oxide, PEO

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
(-CH2CH2O-)n
CAS Number:
MDL number:
UNSPSC 코드:
12352104
PubChem Substance ID:
NACRES:
NA.23

product name

Poly(ethylene oxide), average Mv ~900,000 (nominal), powder

형태

powder

Quality Level

분자량

average Mv ~900,000 (nominal)

포함

200-500 ppm BHT as inhibitor

점도

8,800-17,600 cP, 5 % in H2O(25 °C, Brookfield)(lit.)

전이 온도

Tm 65 °C

density

1.21 g/mL at 25 °C

작용기

hydroxyl

SMILES string

[H]OCCO

InChI

1S/C2H6O2/c3-1-2-4/h3-4H,1-2H2

InChI key

LYCAIKOWRPUZTN-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Poly(ethylene oxide) is a synthetic hydrophilicpolymer available in a number of molecular weights. It can be obtained by thering-opening polymerization of ethylene oxide. This biocompatible polymer can be widely used in the field of biomedical research,tissue engineering and surface functionalization.

애플리케이션

PEO can be used to prepare polymer electrolyte systems for energy storage and conversion devices due its low glass transition temperature and ability to form complex with many alkaline salts.

Owing to its hydration and swelling properties, it is widely used as a precursor to prepare block copolymer micelles for selective drug and gene delivery.

Itcan also be used to fabricate nanofibrous membranes for the adsorption of heavymetal ions.

특징 및 장점

  • Excellent polymer chain flexibility
  • Low toxicity
  • High solvation power
  • Lowglass transition temperature

Storage Class Code

11 - Combustible Solids

WGK

WGK 1

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves, type N95 (US)


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Shih-Heng Chen et al.
International journal of molecular sciences, 20(7) (2019-04-04)
Peritendinous adhesion is a major complication after tendon injury and the subsequent repairs or reconstructions. The degree of adhesion can be reduced by the interposition of a membranous barrier between the traumatized tendon and the surrounding tissue. In the present
Daniel O'Brien et al.
Biomedical microdevices, 21(3), 53-53 (2019-06-17)
The biocompatible and biodegradable polymer poly(glycerol sebacate), or PGS, is a rubber-like material that finds use in several biomedical applications. PGS is often cast into a mold to form desired structures; alternatively, blending PGS with other reinforcing polymers produces viscous
D D Smyth et al.
Cardiovascular drugs and therapy, 4(1), 297-300 (1990-02-01)
Previous studies have demonstrated that Separan AP-30, a drag-reducing polymer, significantly decreased the formation of atherosclerotic plaques in rabbits fed a high-cholesterol diet. Furthermore, Separan AP-273, a polymer similar to but longer than Separan AP-30, markedly increased cardiac output in
M Patel Geeta et al.
Current drug delivery, 6(2), 159-165 (2009-05-20)
Carbamazepine indicated for the control of epilepsy, undergoes extensive hepatic first-pass metabolism after oral administration. A vaginal dosage form of carbamazepine is not commercially available. Conventional suppository having poor retention in the vaginal tract, as they are removed in a
P I Polimeni et al.
Journal of cardiovascular pharmacology, 14(3), 374-380 (1989-09-01)
The acute hemodynamic effects of an intravenously (i.v.) injected poly(ethylene oxide), Polyox WSR N-60K (dose 50 mg/kg), were studied in the open-chest rat anesthetized with sodium pentobarbital. The injectate is one of four drag-reducing polymers known to augment in vitro

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.