Skip to Content
Merck
  • Simultaneous determination of bambuterol and its two major metabolites in human plasma by hydrophilic interaction ultra-performance liquid chromatography-tandem mass spectrometry.

Simultaneous determination of bambuterol and its two major metabolites in human plasma by hydrophilic interaction ultra-performance liquid chromatography-tandem mass spectrometry.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-08-17)
Ting Zhou, Qing Cheng, Chengjuan Zou, Ting Zhao, Shan Liu, Marco Pistolozzi, Evina Tan, Ling Xu, Wen Tan
ABSTRACT

In this study, a rapid and sensitive hydrophilic interaction ultra-performance liquid chromatography-tandem mass spectrometry (HILIC-UPLC-MS/MS) method was developed for simultaneous determination of bambuterol and its two major metabolites monocarbamate bambuterol and terbutaline in human plasma. All samples were simply precipitated using acetonitrile and separated on a UPLC-HILIC column under gradient elution with a mobile phase consisting of acetonitrile and water with the addition of 10mm ammonium acetate and 0.1% formic acid at 0.4 mL/min. The analytes were detected by a Xevo TQ-S tandem mass spectrometer with positive electrospray ionization in multiple reaction monitoring mode. The established method was highly sensitive with the lower limit of quantification (LLOQ) of 10.00 pg/mL for each analyte, and the intra- and inter-day precisions were <12.8%. The analytical runtime within 4.0 min per sample made this method suitable for high throughput determination. The validated method was successfully applied to a clinical pharmacokinetic study of bambuterol in eight healthy volunteers. Furthermore, the effects of the chromatographic conditions on the retention of the analytes on HILIC were investigated, and the benefits of HILIC were evaluated by comparing with a C18 column. The results indicated that liquid-liquid partition and the electrostatic interactions played an important role in the retention of the analytes on HILIC in this study. And HILIC offered particular advantages over RPLC approach in the aspects of the peak symmetry, the column efficiency, and the column pressure.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Ammonium acetate solution, BioUltra, for molecular biology, ~5 M in H2O
Sigma-Aldrich
Sodium carbonate, BioUltra, anhydrous, ≥99.5% (calc. on dry substance, T)
Sigma-Aldrich
Sodium carbonate, BioXtra, ≥99.0%
Sigma-Aldrich
Ammonium acetate solution, for molecular biology, 7.5 M
Supelco
Sodium carbonate concentrate, 0.1 M Na2CO3 in water, eluent concentrate for IC
Sigma-Aldrich
Sodium carbonate-12C, 99.9 atom % 12C
Supelco
Sodium carbonate, reference material for titrimetry, certified by BAM, ≥99.5%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Sodium carbonate, anhydrous, powder, 99.999% trace metals basis
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Sodium carbonate, puriss., meets analytical specification of Ph. Eur., BP, NF, FCC, E500, anhydrous, 99.5-100.5% (calc. to the dried substance)
Sigma-Aldrich
Sodium carbonate, anhydrous, powder or granules, free-flowing, Redi-Dri, ACS reagent, ≥99.5%
Sigma-Aldrich
Sodium carbonate, anhydrous, free-flowing, Redi-Dri, ACS reagent (primary standard), 99.95-100.05% dry basis
Sigma-Aldrich
Sodium carbonate, anhydrous, free-flowing, Redi-Dri, ACS reagent, ≥99.5%
Sigma-Aldrich
Sodium carbonate, anhydrous, free-flowing, Redi-Dri, ReagentPlus®, ≥99.5%
Sigma-Aldrich
Methanol, Absolute - Acetone free
Sigma-Aldrich
Sodium carbonate, ReagentPlus®, ≥99.5%
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Supelco
Sodium carbonate concentrate, Na2CO3 72 mM in water, IC eluent concentrate (20x) for Metrosep A Supp 7
Sigma-Aldrich
Formic acid solution, BioUltra, 1.0 M in H2O
Supelco
Ethyl acetate, analytical standard
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Ethyl acetate, anhydrous, 99.8%
Supelco
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9% (GC)
Supelco
Ethyl Acetate, Pharmaceutical Secondary Standard; Certified Reference Material
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
USP
Methyl alcohol, United States Pharmacopeia (USP) Reference Standard