Skip to Content
Merck
All Photos(1)

Key Documents

Safety Information

41969

Sigma-Aldrich

5-Carboxy-X-rhodamine N-succinimidyl ester

BioReagent, suitable for fluorescence

Sign Into View Organizational & Contract Pricing


About This Item

Empirical Formula (Hill Notation):
C37H33N3O7
CAS Number:
Molecular Weight:
631.67
MDL number:
UNSPSC Code:
12352116
PubChem Substance ID:
NACRES:
NA.32

product line

BioReagent

form

powder

solubility

DMF: soluble
acetonitrile: soluble

fluorescence

λex 575 nm; λem 600 nm in 0.1 M phosphate pH 7.0

suitability

suitable for fluorescence

storage temp.

−20°C

SMILES string

[O-]C(=O)c1cc(ccc1-c2c3cc4CCCN5CCCc(c45)c3[o+]c6c7CCCN8CCCc(cc26)c78)C(=O)ON9C(=O)CCC9=O

InChI

1S/C37H33N3O7/c41-29-11-12-30(42)40(29)47-37(45)22-9-10-23(26(19-22)36(43)44)31-27-17-20-5-1-13-38-15-3-7-24(32(20)38)34(27)46-35-25-8-4-16-39-14-2-6-21(33(25)39)18-28(31)35/h9-10,17-19H,1-8,11-16H2

InChI key

BTTBJYLMDASSAS-UHFFFAOYSA-N

Application

5-Carboxy-X-rhodamine N-succinimidyl ester (ROX-SE) is used as an amine coupling reagent to form 5-carboxy-X-rhodamine (ROX) derivatized compounds such as proteins, nucleic acids and drugs that may be analyzed by fluorescence resonance energy transfer (FRET) and fluorescence quenching applications.Labeling reagent for preparation of charge-modified dye-labeled ddNTPs to "direct-load" DNA sequencing.

Other Notes

Labeling reagent for prepn. of charge-modified dye-labeled ddNTPs to "direct-load" DNA sequencing

Pictograms

Exclamation mark

Signal Word

Warning

Hazard Statements

Hazard Classifications

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

Target Organs

Respiratory system

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Personal Protective Equipment

dust mask type N95 (US), Eyeshields, Gloves

Regulatory Listings

Regulatory Listings are mainly provided for chemical products. Only limited information can be provided here for non-chemical products. No entry means none of the components are listed. It is the user’s obligation to ensure the safe and legal use of the product.

JAN Code

41969-25MG-F:
41969-5MG-F:
41969-VAR-F:
41969-BULK-F:
41969-5MG-BULK-F:


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Jonathan F Lovell et al.
Journal of the American Chemical Society, 133(46), 18580-18582 (2011-10-27)
Photodynamic therapy (PDT) stands to benefit from improved approaches to real-time treatment monitoring. One method is to use activatable photosensitizers that can both induce cell death (via singlet oxygen) and monitor it (via caspase detection). Here, we report porphyrins as
Dong-Shan Xiang et al.
The Analyst, 137(16), 3787-3793 (2012-07-06)
We have developed a dual color fluorescence quantitative detection method for specific single-stranded DNA with molecular beacons (MBs) and nucleic acid dye SYBR Green I by synchronous scanning fluorescence spectrometry. It is demonstrated by a reverse-transcription oligonucleotide sequence (target DNA
Yong Huang et al.
Chemistry (Weinheim an der Bergstrasse, Germany), 17(26), 7313-7319 (2011-05-11)
A highly sensitive and selective assay based on a novel enzyme-responsive multicolor gold nanobeacon has been developed for the multiplex detection of endonucleases, a group of very important nucleases. The nanobeacon takes advantage of the high specificity of DNA cleavage
Xia Xiang et al.
Analytica chimica acta, 751, 155-160 (2012-10-23)
The development of simple and inexpensive DNA detection strategy is very significant for droplet-based microfluidic system. Here, a droplet-based biosensor for multiplexed DNA analysis is developed with a common imaging device by using fluorescence-based colorimetric method and a graphene nanoprobe.
Ting Qiu et al.
The Analyst, 135(9), 2394-2399 (2010-08-03)
A new strategy for quantitatively detecting micrococcal nuclease (MNase) is proposed using electrostatic interaction-based fluorescence resonance energy transfer (FRET) between positively charged QDs and negatively charged dye-labeled single-stranded DNA (dye-ssDNA). Herein, we have made our attempt to develop a strategy

Articles

Fluorescent Labeling of Peptides

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service