ChemiSCREEN Membrane Preparation Recombinant Human CB2 Cannabinoid Receptor
Human CB2 GPCR membrane preparation for Radioligand binding Assays & GTPγS binding.
Synonym(s):
Cannabinoid receptor membrane prep, Human CB2 membrane prep
About This Item
Recommended Products
biological source
human
Quality Level
recombinant
expressed in CHO cells
manufacturer/tradename
ChemiScreen
Chemicon®
technique(s)
ligand binding assay: suitable (GTPγS)
radioligand binding assay (RLBA): suitable
NCBI accession no.
UniProt accession no.
shipped in
dry ice
General description
Quality
10 µg/well | 5 µg/well | |
---|---|---|
Signal:Background | 33.5 | 25.2 |
Specific Binding (cpm) | 7336 | 6207 |
SPECIFICATIONS: 1 unit = 5 μg membrane preparation
Bmax: 50 pmol/mg
Kd: 2.7 nM
Specifications
RECOMMENDED ASSAY CONDITIONS: Membranes are mixed with radioactive ligand and unlabeled competitor (see Figures 1 and 2 for concentrations tested) in binding buffer in a nonbinding 96-well plate, and incubated for 1-2 h. Prior to filtration, an FC 96-well harvest plate (Millipore cat. # MAHF C1H) is coated with 0.33% polyethyleneimine for 30 min, then washed with 50mM HEPES, pH 7.4, 0.5% BSA. Binding reaction is transferred to the filter plate, and washed 3 times (1 mL per well per wash) with Wash Buffer. The plate is dried and counted.
Binding buffer: 50 mM Hepes, pH 7.4, 5 mM MgCl2, 1 mM CaCl2, 0.2% BSA, filtered and stored at 4°C.
Radioligand: [3H]-CP55940 (Perkin Elmer #NET1051)
Wash Buffer: 50 mM Hepes, pH 7.4, 500 mM NaCl , 0.1% BSA, filtered and stored at 4°C.
One package contains enough membranes for at least 200 assays (units), where an unit is the amount of membrane that will yield greater than 10-fold signal:background with 3H-labeled CP55,940 at 2.5 nM
Physical form
Packaging method: Membranes proteins were adjusted to the indicated concentration in packaging buffer, rapidly frozen, and stored at -80°C.
Legal Information
Storage Class Code
12 - Non Combustible Liquids
WGK
WGK 2
Flash Point(F)
Not applicable
Flash Point(C)
Not applicable
Regulatory Listings
Regulatory Listings are mainly provided for chemical products. Only limited information can be provided here for non-chemical products. No entry means none of the components are listed. It is the user’s obligation to ensure the safe and legal use of the product.
JAN Code
HTS020M:
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.