Skip to Content
Merck
All Photos(1)

Documents

Safety Information

HCYTA-60K

Millipore

MILLIPLEX® Human Cytokine/Chemokine/Growth Factor Panel A - Immunology Multiplex Assay

Synonym(s):

Human cytokine multiplex kit, Luminex® human cytokine immunoassay, Millipore human cytokine panel

Sign Into View Organizational & Contract Pricing


About This Item

species reactivity

human

Quality Level

manufacturer/tradename

Milliplex®

technique(s)

multiplexing: suitable

detection method

fluorometric (Luminex® xMAP®)

storage temp.

2-8°C

General description

Cytokines are immunomodulatory polypeptides that play key roles in both adaptive and innate immune responses.“Cytokine” is a general term used for a diverse group of soluble proteins and peptides which act as regulators under both normal and pathological conditions to modulate the functional activities of individual cells and tissues. These proteins also mediate direct interactions between cells and regulate processes taking place in the extracellular environment. Cytokines differ from hormones in that they act on a wider spectrum of target cells. The cytokine group of proteins includes lymphokines, interferons, colony stimulating factors and chemokines. Growth factors are involved in the stimulation of target cell survival, proliferation, differentiation with effects on angiogenesis, vasculogenesis, cell migration, apoptosis, wound healing and embryogenesis.Cytokine, chemokine and growth factor research plays a significant role in achieving a deeper understanding of the immune system and its multi-faceted response to most antigens, especially those responses that make up the inflammatory process, and disease states such as infectious disease, osteoarthritis, respiratory disease, IBD, sepsis, allergic reactions as well as neurologic, metabolic and cardiovascular disease and even cancer. MILLIPLEX® offers the broadest selection of analytes across a wide range of disease states and species. Once the analytes of interest have been identified, you can rely on the quality that we build into each kit to produce results you can trust. In addition to the assay characteristics listed in the protocol, other performance criteria evaluated during the verification process include: cross-reactivity, dilution linearity, kit stability, and sample behavior (e.g. detectability and stability). Each MILLIPLEX® panel and kit includes:Quality controls (QCs) to qualify assay performanceComparison of standard (calibrator) and QC lots to a reference lot to ensure lot-to-lot consistencyOptimized serum matrix to mimic native analyte environment in serum and plasma samplesDetection antibody cocktails designed to yield consistent analyte profiles within panelIn addition each panel and kit meets stringent manufacturing criteria to ensure batch-to-batch reproducibility. The MILLIPLEX® Human Cytokine/Chemokine/Growth Factor Panel A thus enables you to focus on the therapeutic potential of cytokines and the modulation of cytokine expression. Coupled with the Luminex® xMAP platform in a magnetic bead format, you receive the advantage of ideal speed and sensitivity, allowing quantitative multiplex detection of dozens of analytes simultaneously, which can dramatically improve productivity.

Application

Simultaneously analyze up to 48 multiple cytokine, chemokine, and growth factor biomarkers with Bead-Based Multiplex Assays using the Luminex technology, in human serum, plasma and cell culture samples.This is an overnight or two-hour incubation assay.This assay requires 25 μL of neat plasma or serum (1:100 dilution for RANTES) or 25 μL cell culture supernatant per well.This kit may be used for the analysis of any or all of the Human Cytokine/Chemokine/Growth Factor Panel A analytes in human tissue/cell lysate and culture supernatant samples and serum or plasma samples.RANTES cannot be plexed with other cytokines in this panel due to a required 1:100 dilution of plasma/serum samples.Analytes available:sCD40L;EGF;Eotaxin;FGF-2;Flt-3 ligand;Fractalkine;G-CSF;GM-CSF;GROα;IFNα2;IFNγ;IL-1α;IL-1β;IL-1ra;IL-2;IL-3;IL-4;IL-5;IL-6;IL-7;IL-8;IL-9;IL-10;IL-12 (p40);IL-12 (p70);IL-13;IL-15;IL-17A;IL-17E/IL-25;IL-17F;IL-18;IL-22;IL-27;IP-10;MCP-1;MCP-3;M-CSF;MDC (CCL22);MIG;MIP-1α;MIP-1β;PDGF-AA;PDGF-AB/BB;RANTES;TGFα;TNFα;TNFβ;VEGF-A

Features and Benefits

Design your multiplex kit by choosing available analytes within this panel.

Packaging

96-well plate

Storage and Stability

Recommended storage for kit components is 2 - 8°C.

Legal Information

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Signal Word

Danger

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

Target Organs

Respiratory Tract

Storage Class Code

10 - Combustible liquids

WGK

WGK 3


Regulatory Listings

Regulatory Listings are mainly provided for chemical products. Only limited information can be provided here for non-chemical products. No entry means none of the components are listed. It is the user’s obligation to ensure the safe and legal use of the product.

PDSCL

Please refer to KIT Component information

PRTR

Please refer to KIT Component information

FSL

Please refer to KIT Component information

ISHL Indicated Name

Please refer to KIT Component information

ISHL Notified Names

Please refer to KIT Component information

Cartagena Act

Please refer to KIT Component information

JAN Code

キットコンポーネントの情報を参照してください


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Teslin S Sandstrom et al.
Journal of virology, 95(9) (2021-02-12)
The use of unique cell surface markers to target and eradicate HIV-infected cells has been a longstanding objective of HIV-1 cure research. This approach, however, overlooks the possibility that intracellular changes present within HIV-infected cells may serve as valuable therapeutic
Qi Wang et al.
Frontiers in immunology, 13, 995223-995223 (2022-09-27)
In primary biliary cholangitis (PBC), the levels of serum IL-2 were involved in liver inflammation and immune changes. This study aimed to investigate the prognostic significance of serum IL-2 combined with total bilirubin (TBIL) in liver failure and cytokine changes
Myung-Ho Kim et al.
The Journal of infectious diseases (2021-05-27)
We analyzed the plasma levels of interferons and cytokines, and the expression of interferon-stimulated genes in peripheral blood mononuclear cells in COVID-19 patients with different disease severity. Mild patients exhibited transient type I interferon responses, while ICU patients had prolonged
Yiwei Zhao et al.
Fertility and sterility, 115(4), 1044-1053 (2020-12-05)
To compare the changing peripheral levels of inflammation-related cytokine profile during a 9-day period after blastocyst transfer between women who did and did not conceive. Prospective, observational, and longitudinal study. University-affiliated hospital. Forty-seven women with infertility who were undergoing single
Myung-Ho Kim et al.
medRxiv : the preprint server for health sciences (2021-03-25)
We analyzed the plasma levels of interferons and cytokines, and the expression of interferon-stimulated genes in peripheral blood mononuclear cells in COVID-19 patients with different disease severity. Mild patients exhibited transient type I interferon responses, while ICU patients had prolonged

Related Content

Cytokine multiplex assays allow researchers to easily investigate the immune system. The MILLIPLEX® Human Cytokine/Chemokine/Growth Factor Panel A combines 48 individual immune factors in a single cytokine multiplex assay panel with the flexibility of choosing any analyte combination or selecting a premixed kit.

Learn how immunoassays are used in cosmetics and personal care research to discover potential harmful effects of cosmetics products, and assess markers of inflammation, sensitization, aging, and tissue regeneration among others.

See how MILLIPLEX® multiplex immunoassays offer researchers the ability to simultaneously quantitate a large number of human cytokines, chemokines, and growth factors, and detect human immunoglobulins against SARS-CoV-2 antigens, to better understand the immune response to COVID-19, including cytokine storm.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service