Passa al contenuto
Merck
Tutte le immagini(1)

Documenti

821455

TSKgel® ODS-100V (5 µm) HPLC Columns

L x I.D. 15 cm × 4.6 mm, C18 (octadecyl) phase

Sinonimo/i:

TSKgel® Reversed Phase HPLC Column

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
41115711
eCl@ss:
32110501

product name

TSKgel® ODS-100V HPLC Column, phase C18 (octadecyl), L × I.D. 15 cm × 4.6 mm, 5 μm particle size

Materiali

stainless steel hardware

agenzia

suitable for USP L1

Nome Commerciale

TSKgel®

Produttore/marchio commerciale

Tosoh ODS-100V, 21455

Grado di funzionalizzazione

15% Carbon, endcapped with bifunctional dialkylsilane

Parametri

0-100% organic solvent
1.0 mL/min standard flow rate
10-50 °C temperature
180 bar max. pressure

tecniche

HPLC: suitable

Lungh. × D.I.

15 cm × 4.6 mm

Area superficiale

450 m2/g

Matrice

silica particle platform

Gruppo funzionale matrice

C18 (octadecyl) phase

Dimensione particelle

5 μm

Dimensione pori

100 Å

pH di lavoro

2.0-7.5

Tecnica di separazione

reversed phase

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Descrizione generale

TSKgel® ODS-100V and TSKgel ODS-100Z columns incorporate the best-in-class surface properties to limit secondary interactions of basic, acidic and chelating compounds. Take advantage of the benefits of high column efficiency and symmetrical peak shapes to reduce your analysis and method development time! The ultra high purity Type B base silica contains negligible amounts of metal ion impurities. Combined with monomeric bonding chemistry, this silica makes the best general purpose Reversed Phase columns suitable for the most demanding separations in quality control as well as in research and development. TSKgel ODS-100V columns have a lower carbon content than ODS-100Z columns, making the bonded phase surface 100% water wettable and the preferred choice to retain polar metabolites.

Applicazioni

TSKgel® ODS-100V HPLC Column may be used for the separation of:
  • Docetaxel in human plasma during its determination by high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) combined with electrospray ionization (ESI) and multiple reaction monitoring (MRM) detection.
  • Constituents of Chinese medicine Niu Huang Jie Du Pill during their analysis by HPLC combined with diode array detection (DAD).
  • Organic and inorganic selenium in diet supplements during the determination using HPLC-ESI-MS/MS with MRM detection.
  • Estrogenic compounds 8-prenylnaringenin, zearalenone, α- and β-zearalenol in beer during their identification using LC-ESI-MS with single ion monitoring (SIM) detection.
  • Lincomycin, spectinomycin and its impurities in pharmaceutical products during their analysis by HPLC combined with charged aerosol detection (CAD) as well as HPLC coupled to time-of flight mass spectrometer (TOFMS) with ESI.

Stato fisico

Shipped in acetonitrile.

Prodotti consigliati

Discover LiChropur reagents ideal for HPLC or LC-MS analysis

Note legali

TSKgel is a registered trademark of Tosoh Corporation

Choose from one of the most recent versions:

Certificati d'analisi (COA)

Lot/Batch Number

Sorry, we don't have COAs for this product available online at this time.

If you need assistance, please contact Servizio Clienti

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Development of high performance liquid chromatography methods with charged aerosol detection for the determination of lincomycin, spectinomycin and its impurities in pharmaceutical products
Stypulkowska K, et al.
Journal of Pharmaceutical and Biomedical Analysis, 112(1), 8-14 (2015)
Simultaneous quantitation and identification of organic and inorganic selenium in diet supplements by liquid chromatography with tandem mass spectrometry.
Zembrzuska J, et al.
Food Chemistry, 142(3), 178-187 (2014)
A rapid and sensitive LC/ESI-MS/MS method for quantitative analysis of docetaxel in human plasma and its application to a pharmacokinetic study.
Yamaguchi H, et al.
Journal of Chromatography. B, Biomedical Sciences and Applications, 893, 157-161 (2012)
Qualitative and quantitative analysis of traditional Chinese medicine Niu Huang Jie Du Pill using ultra performance liquid chromatography coupled with tunable UV detector and rapid resolution liquid chromatography coupled with time-of-flight tandem mass spectrometry
Liang X, et al.
Journal of Pharmaceutical and Biomedical Analysis, 51(3), 565-571 (2010)
Direct determination of the estrogenic compounds 8-prenylnaringenin, zearalenone, ?- and ?-zearalenol in beer by liquid chromatography-mass spectrometry.
Maragou NC, et al.
Journal of Chromatography A, 1202(1), 47-57 (2008)

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.