Supelco

Ascentis® C8 (3 µm) HPLC Columns

L × I.D. 10 cm × 2.1 mm, HPLC Column

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
41115700
eCl@ss:
32110501
NACRES:
SB.52

product name

Ascentis® C8 HPLC Column, 3 μm particle size, L × I.D. 10 cm × 2.1 mm

Materiali

stainless steel column

agenzia

suitable for USP L7

Nome Commerciale

Ascentis®

Caratteristiche

endcapped

Produttore/marchio commerciale

Ascentis®

Confezionamento

1 ea of

Grado di funzionalizzazione

15% Carbon loading

Parametri

≤70 °C temp. range
400 bar pressure (5801 psi)

tecniche

HPLC: suitable
LC/MS: suitable

Lungh. × D.I.

10 cm × 2.1 mm

Area superficiale

450 m2/g

Copertura della superficie

4.0 μmol/m2

Impurezze

<5 ppm metals

Matrice

fully porous particle
silica gel high purity, spherical

Gruppo funzionale matrice

C8 (octyl) phase

Dimensione particelle

3 μm

Dimensione pori

100 Å

operating pH range

2-8

applicazioni

food and beverages

Tecnica di separazione

reversed phase

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Descrizione generale

The Ascentis family of columns is the fourth generation of HPLC column technology from Supelco scientists. Ascentis columns are bonded on high purity, 100 Angstrom silica including 3, 5, and 10 micron particle size. Columns are designed for small molecule applications and are scalable from micro columns (1.0 mm I.D.) to preparative dimensions (50 mm I.D.). The family includes C18, C8, Phenyl, Si and embedded polar group phase, RP-Amide.

The Ascentis C8 is a highly reproducible column with excellent selectivity towards polar compounds. The phase excells in highly aqueous mobile phases as well as high organic mobile phases.

Caratteristiche e vantaggi

  • Superior retention for hydrophobic molecules
  • Excellent peak shape
  • Low bleed LC-MS separations

Prodotti consigliati

Discover LiChropur reagents ideal for HPLC or LC-MS analysis

Note legali

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany

Prodotti correlati

N° Catalogo
Descrizione
Determinazione del prezzo

Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Mahmoud Hasan et al.
Journal of pharmaceutical and biomedical analysis, 100, 341-347 (2014-09-10)
Clodronate belongs to the class of bisphosphonates which are used for the treatment of bone disorders. Due to its high polarity it has a low and highly variable oral bioavailability which results in low plasma concentrations and requires sensitive bioanalytical
Ebenezer B Asafu-Adjaye et al.
Journal of pharmaceutical and biomedical analysis, 43(5), 1854-1859 (2007-02-16)
Gastrointestinal stability of venlafaxine was evaluated in vitro in simulated gastric (SGF) and intestinal (SIF) fluids using a stability indicating HPLC method. The method was validated using a 5 microm Ascentis C18 column (150 mm x 4.6 mm) and mobile
Luana Magalhães et al.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 1008, 98-107 (2015-12-08)
Nucleoside triphosphate diphosphohydrolase (NTPDase) is an enzyme belonging to the apyrase family that participates in the hydrolysis of the nucleosides di- and triphosphate to the corresponding nucleoside monophosphate. This enzyme underlies the virulence of parasites such as Leishmania. Recently, an
Ugandar Reddy Inugala et al.
Journal of chromatographic science, 51(5), 453-459 (2012-10-13)
This paper describes the development of a rapid, novel, stability-indicating gradient reversed-phase high-performance liquid chromatographic method and associated system suitability parameters for the analysis of naproxcinod in the presence of its related substances and degradents using a quality-by-design approach. All
Sreenivasa Rao Chitturi et al.
Journal of pharmaceutical and biomedical analysis, 55(1), 31-47 (2011-02-15)
This paper proposes a simple and selective RP-HPLC method for the determination of process impurities and degradation products (degradants) of atazanavir sulfate (ATV) drug substance. Chromatographic separation was achieved on Ascentis(®) Express C8, (150mm×4.6mm, 2.7μm) column thermostated at 30°C under

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.